battery_compatibility:lg_chem_resu [2019-01-21 10:39] – [DISQUS] ictbeheer | battery_compatibility:lg_chem_resu [2019-08-15 12:24] (current) – replace venus-device with GX device guy_stewart | ||
---|---|---|---|
Line 5: | Line 5: | ||
The only inverter/ | The only inverter/ | ||
- | === A Venus device is required (either Color Control GX (CCGX) or the VENUS GX) === | + | === A GX device is required (either Color Control GX (CCGX) or the VENUS GX) === |
- | It is essential to use the CAN-bus connection of the [[venus-os: | + | It is essential to use the CAN-bus connection of the [[venus-os: |
The minimum required firmware version for the [[https:// | The minimum required firmware version for the [[https:// | ||
Line 22: | Line 22: | ||
* LG battery policy is to only charge the battery to 97% or 98%. It is normal for the battery not to charge to 100%. | * LG battery policy is to only charge the battery to 97% or 98%. It is normal for the battery not to charge to 100%. | ||
- | ==== Color Control GX or Venus GX required ==== | + | ==== GX device |
- | To use the LG Chem Resu and Victron equipment, it is necessary to use a [[venus-os: | + | To use the LG Chem Resu and Victron equipment, it is necessary to use a [[venus-os: |
- | Do not attempt firmware updates using the LG Chem battery for power until you can confirm that the battery is connected and showing on the [[venus-os: | + | Do not attempt firmware updates using the LG Chem battery for power until you can confirm that the battery is connected and showing on the [[venus-os: |
==== Wiring of communication cables ==== | ==== Wiring of communication cables ==== | ||
- | Use the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018. Plug the side which is labeled Battery BMS into the LG Chem Resu BMS. Plug the side labeled Victron VE.Can into the [[venus-os: | + | Use the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018. Plug the side which is labeled Battery BMS into the LG Chem Resu BMS. Plug the side labeled Victron VE.Can into the [[venus-os: |
Then, plug a [[https:// | Then, plug a [[https:// | ||
Line 69: | Line 69: | ||
Then: | Then: | ||
- Sustain voltage: 50V | - Sustain voltage: 50V | ||
- | - Do not change the dynamic cut-off values, | + | - The dynamic cut-off values |
- | - Same for the restart offset | + | - Leave the default |
==== Color Control GX Configuration ==== | ==== Color Control GX Configuration ==== | ||
Line 97: | Line 96: | ||
- Switch the Multis/ | - Switch the Multis/ | ||
+ | |||