battery_compatibility:lg_chem_resu
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| battery_compatibility:lg_chem_resu [2017-07-16 08:14] – [Notes] mvader | battery_compatibility:lg_chem_resu [2025-06-02 09:37] (current) – [Compatible Victron products] guy_stewart | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Victron & LG Chem Resu ====== | ====== Victron & LG Chem Resu ====== | ||
| - | ==== Compatible Victron products | + | ==== Compatibility |
| - | The MultiPlus 48/ | + | **NOTE - This document is now End-of-Life and for archive purposes only.** |
| + | |||
| + | LG no longer supports the Resu models that were previously compatible. | ||
| + | |||
| + | The only Victron inverter/ | ||
| + | |||
| + | === A GX device is required (either Color Control GX (CCGX) or the VENUS GX) === | ||
| + | |||
| + | It is essential to use the CAN-bus connection of the [[venus-os: | ||
| + | |||
| + | The minimum required firmware version for the [[https:// | ||
| - | And always a [[https:// | ||
| ==== Notes ==== | ==== Notes ==== | ||
| Line 11: | Line 20: | ||
| * It can only be used in On-grid systems, for self-consumption. Not for off-grid systems. | * It can only be used in On-grid systems, for self-consumption. Not for off-grid systems. | ||
| * Derating, based on the dynamic LG Resu charge- and discharge limits: | * Derating, based on the dynamic LG Resu charge- and discharge limits: | ||
| - | * Minimum CCGX version is v1.72 | + | * Minimum CCGX version is v2.15 |
| * The derating mechanism is not very precise yet. In other words, do not expect a discharge limit of 30A to result in a precise discharge of 30A. | * The derating mechanism is not very precise yet. In other words, do not expect a discharge limit of 30A to result in a precise discharge of 30A. | ||
| * Actual charge- and discharge limits are visible in the Parameters page. See screenshot below. | * Actual charge- and discharge limits are visible in the Parameters page. See screenshot below. | ||
| + | * LG batteries Resu batteries may only be used with MPPT Solar Chargers with the VE.Direct port. The VE.Can MPPTs are not supported. | ||
| + | * LG battery policy is to only charge the battery to 97% or 98%. It is normal for the battery not to charge to 100%. | ||
| + | |||
| + | ==== GX device required ==== | ||
| + | To use the LG Chem Resu and Victron equipment, it is necessary to use a [[venus-os: | ||
| + | Do not attempt firmware updates using the LG Chem battery for power until you can confirm that the battery is connected and showing on the [[venus-os: | ||
| ==== Wiring of communication cables ==== | ==== Wiring of communication cables ==== | ||
| - | To use the LG Chem Resu and Victron equipment, it is necessary to use a CCGX. It takes care of sending | + | Use the //VE.Can to CAN-bus BMS type B Cable//, part number ASS030720018. Plug the side which is labeled Battery BMS into the LG Chem Resu BMS. Plug the side labeled Victron VE.Can into the [[venus-os: |
| - | A special RJ-45 cable is necessary to connect | + | Then, plug a [[https:// |
| - | ^ Function ^ VE.Can RJ-45 ^ LG Chem RJ-45 ^ | + | More information about the cable can be found in [[battery_compatibility: |
| - | | GND | Pin 3 | Pin 2 | | + | |
| - | | CAN-L | + | |
| - | | CAN-H | + | |
| - | Place a VE.Can terminator in the empty socket | + | Without properly connecting this cable, the battery will stop charging/ |
| === Note on the latest LG Resu models (3.3, 6.5 and 10) === | === Note on the latest LG Resu models (3.3, 6.5 and 10) === | ||
| Line 34: | Line 46: | ||
| === General tab === | === General tab === | ||
| - | - Enabled | + | - Check " |
| - | - Set the battery capacity to 50Ah times the number of battery modules. | + | |
| - Enter the battery capacity: | - Enter the battery capacity: | ||
| - Resu 6.4 - 126 Ah | - Resu 6.4 - 126 Ah | ||
| Line 43: | Line 54: | ||
| - Resu 6.5 - 126 Ah | - Resu 6.5 - 126 Ah | ||
| - Resu 10 - 189 Ah | - Resu 10 - 189 Ah | ||
| + | - The other parameters (" | ||
| === Charger tab === | === Charger tab === | ||
| Line 48: | Line 60: | ||
| | Battery type | Lithium | | Battery type | Lithium | ||
| | Charge curve | Fixed | Fixed | | | Charge curve | Fixed | Fixed | | ||
| - | | Absorption voltage | + | | Absorption voltage |
| - | | Float voltage | + | | Float voltage |
| | Absorption time | 1 Hr | 1 Hr | | | Absorption time | 1 Hr | 1 Hr | | ||
| Note: make sure to double check the float voltage after completing Assistants. | Note: make sure to double check the float voltage after completing Assistants. | ||
| - | === Hub-4 Assistant === | + | === ESS Assistant === |
| Select the fourth battery type: | Select the fourth battery type: | ||
| Line 61: | Line 73: | ||
| Then: | Then: | ||
| - Sustain voltage: 50V | - Sustain voltage: 50V | ||
| - | - Do not change the dynamic cut-off values, | + | - The dynamic cut-off values |
| - | - Same for the restart offset | + | - Leave the default |
| ==== Color Control GX Configuration ==== | ==== Color Control GX Configuration ==== | ||
| - | * Enable | + | * Select |
| * After properly wiring and setting up, the LG Resu will be visible as a battery in the device list:{{ : | * After properly wiring and setting up, the LG Resu will be visible as a battery in the device list:{{ : | ||
| Line 88: | Line 99: | ||
| - Restore the battery top cover again. | - Restore the battery top cover again. | ||
| - Switch the Multis/ | - Switch the Multis/ | ||
| + | |||
| ===== DISQUS ===== | ===== DISQUS ===== | ||
| ~~DISQUS~~ | ~~DISQUS~~ | ||
| + | |||
battery_compatibility/lg_chem_resu.1500185683.txt.gz · Last modified: by mvader