battery_compatibility:freedomwon
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| battery_compatibility:freedomwon [2023-10-31 10:59] – CVL edits. warwickchapman | battery_compatibility:freedomwon [2026-02-27 10:50] (current) – [Large Parallel Banks (>6000A Current Limits)] iburger | ||
|---|---|---|---|
| Line 140: | Line 140: | ||
| For LiTE batteries in parallel, the second RJ45 socket is used to link the next battery in the line onto the CAN Bus network. The termination resistor is installed in the last battery in the CAN Bus line. Refer to [[https:// | For LiTE batteries in parallel, the second RJ45 socket is used to link the next battery in the line onto the CAN Bus network. The termination resistor is installed in the last battery in the CAN Bus line. Refer to [[https:// | ||
| - | For eTower batteries in parallel, the first battery must be programmed as the Master by setting it to Address 01 using the DIP switches, while the rest of the eTower modules connected to the DC bus are programmed as Slaves by default when they have addresses of 02 or higher. Refer to the [[https:// | + | For eTower batteries in parallel, the first battery must be programmed as the Master by setting it to Address 01 using the DIP switches, while the rest of the eTower modules connected to the DC bus are programmed as Slaves by default when they have addresses of 02 or higher. Refer to the [[https:// |
| **eTower DIP Settings** | **eTower DIP Settings** | ||
| Line 261: | Line 261: | ||
| Adjust the maximum current on the MPPT's to ensure that the combined total charge power cannot exceed the maximum rated charge current for the LiTE or LiTE's in the system. | Adjust the maximum current on the MPPT's to ensure that the combined total charge power cannot exceed the maximum rated charge current for the LiTE or LiTE's in the system. | ||
| - | ===== Large Parallel Banks (>3000A Current Limits) ===== | + | ===== Large Parallel Banks (>6500A Current Limits) ===== |
| - | The CAN Bus hexadecimal message format that the Victron GX controller uses cannot accept a number larger than 3000 for the Charge Current Limit (CCL) and the Discharge Current Limit (DCL). | + | The CAN Bus hexadecimal message format that the Victron GX controller uses cannot accept a number larger than 6500 for the Charge Current Limit (CCL) and the Discharge Current Limit (DCL). |
| - | Freedom Won LiTE batteries are designed for very high current capabilities, | + | Freedom Won LiTE batteries are designed for very high current capabilities, |
| - | The designer must refer to the LiTE specification sheet to determine if the total of the CCL or DCL for all the batteries connected on the system will add up to a value greater than 3000A. | + | The designer must refer to the LiTE specification sheet to determine if the total of the CCL or DCL for all the batteries connected on the system will add up to a value greater than 6500A. |
| - | If this is the case, the commissioning technician must arrange with Freedom Won technical support ([[support@freedomwon.co.za]]) to reduce these limits so that the total falls at or under 3000A. This is achieved simply and quickly by the Freedom Won support team installing a custom profile into the battery via a remote desktop session using a computer connected to the master battery. | + | If this is the case, the commissioning technician must arrange with Freedom Won technical support ([[support@freedomwon.co.za]]) to reduce these limits so that the total falls at or under 6500A. This is achieved simply and quickly by the Freedom Won support team installing a custom profile into the battery via a remote desktop session using a computer connected to the master battery. |
| Please refer to the note below regarding scheduling time with support if required. | Please refer to the note below regarding scheduling time with support if required. | ||
battery_compatibility/freedomwon.1698746393.txt.gz · Last modified: by warwickchapman