User Tools

Site Tools


battery_compatibility:byd_b-box

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
battery_compatibility:byd_b-box [2025-10-06 08:43] – [Victron & BYD] guy_stewartbattery_compatibility:byd_b-box [2026-08-14 11:34] (current) guy_stewart
Line 1: Line 1:
 ====== Victron & BYD ====== ====== Victron & BYD ======
    
-^  Battery ^  Pro 2.5-10.0 ^  Pro 12.8 & 13.8 ^  L 3.5-14.0 ^ Premium LVL 15.4 ^ Premium LVS 4.0 ^ LV Flex 5 ^ LV5.0+ ^ 
-|  Appearance |  {{ :battery_compatibility:byd-bbox2-5.jpg?nolink&100 |}}|  {{ :battery_compatibility:byd-bbox13-8.jpg?nolink&100 |}}|  {{ :battery_compatibility:byd-l3-5.jpg?nolink&100 |}}| {{:battery_compatibility:byd_premium_lvl.jpg?nolink&150|}}  |  {{:battery_compatibility:byd_lvs.jpg?nolink&80}}  | {{:battery_compatibility:byd_flex.jpg?100|}} | {{:battery_compatibility:byd5.0_.png?100|}} | 
-|  ESS |  yes|  yes|  yes|  yes|  yes|  yes|  yes| 
-|  Grid Backup|  yes|  yes|  yes |   yes|  yes|  yes|  yes| 
-|  Off-Grid|  yes|  yes|  no|  yes|  yes|  yes|  yes| 
-|  Module capacity|  2.5 kWh |  13.8 kWh |  3.5 kWh|   15.36 kWh|  4.0 kWh|  5.0 kWh |  5.12 kWh | 
-|  Module limit |  32|  32|  12|  64|  64|  64|  32| 
-|  Max capacity|  80 kWh|  441.6 kWh|  42 kWh|  983 kWh|  256 kWh|  320 kWh|  163.84 kWh| 
 ===== 1. Product & System compatibility ===== ===== 1. Product & System compatibility =====
  
Line 21: Line 13:
  
 For Off-grid systems, its strongly recommend to make sure there is a minimum of DC-Coupled PV (= MPPT Solar Charger) in the system. Ie. not only AC-Coupled PV. Also, minimum battery configuration, and factor 1.0 are always important to adhere to, and even more so in case of Off-grid systems. Both BYD and Victron will be reluctant or even refusing to give support to systems that are not sized according to the minimum battery configuration table. For Off-grid systems, its strongly recommend to make sure there is a minimum of DC-Coupled PV (= MPPT Solar Charger) in the system. Ie. not only AC-Coupled PV. Also, minimum battery configuration, and factor 1.0 are always important to adhere to, and even more so in case of Off-grid systems. Both BYD and Victron will be reluctant or even refusing to give support to systems that are not sized according to the minimum battery configuration table.
 +
 +
 +^  Battery ^  Pro 2.5-10.0 ^  Pro 12.8 & 13.8 ^  L 3.5-14.0 ^ Premium LVL 15.4 ^ Premium LVS 4.0 ^ LV Flex 5 ^ LV5.0+/LV5.0+ (2026) ^
 +|  Appearance |  {{ :battery_compatibility:byd-bbox2-5.jpg?nolink&100 |}}|  {{ :battery_compatibility:byd-bbox13-8.jpg?nolink&100 |}}|  {{ :battery_compatibility:byd-l3-5.jpg?nolink&100 |}}| {{:battery_compatibility:byd_premium_lvl.jpg?nolink&150|}}  |  {{:battery_compatibility:byd_lvs.jpg?nolink&80}}  | {{:battery_compatibility:byd_flex.jpg?100|}} | {{:battery_compatibility:bydlv.png?120|}} | 
 +|  ESS |  yes|  yes|  yes|  yes|  yes|  yes|  yes|
 +|  Grid Backup|  yes|  yes|  yes |   yes|  yes|  yes|  yes|
 +|  Off-Grid|  yes|  yes|  no|  yes|  yes|  yes|  yes|
 +|  Module capacity|  2.5 kWh |  13.8 kWh |  3.5 kWh|   15.36 kWh|  4.0 kWh|  5.0 kWh |  5.12 kWh |
 +|  Module limit |  32|  32|  12|  64|  64|  64|  32|
 +|  Max capacity|  80 kWh|  441.6 kWh|  42 kWh|  983 kWh|  256 kWh|  320 kWh|  163.84 kWh|
 +
  
 === 1.2 A GX device is required, eg Cerbo GX, etc ===  === 1.2 A GX device is required, eg Cerbo GX, etc === 
Line 61: Line 64:
 | B-BOX Premium LVS 4.0     | | B-BOX Premium LVS 4.0     |
 | B-BOX LV Flex 5.0      | | B-BOX LV Flex 5.0      |
 +| B-BOX LV5.0+/LV5.0+ (2026)      |
  
 BYD also releases firmware update for their BMU and BMS.  BYD also releases firmware update for their BMU and BMS. 
Line 179: Line 183:
 |     EasySolar & EasySolar-II 48/3000/35-50 MPPT150/70|  1|  3|  2|  4| |     EasySolar & EasySolar-II 48/3000/35-50 MPPT150/70|  1|  3|  2|  4|
 |   EasySolar 48/5000/70-100 MPPT150/100|  2|  5|  2|  6| |   EasySolar 48/5000/70-100 MPPT150/100|  2|  5|  2|  6|
 +
 +
 +=== Battery Modules Required - LV5.0+/LV5.0+(2026) ===
 +^ Inverter/Charger ^ Single Phase ^^^ Three Phase ^^^
 +^ ::: ^ On-Grid ^ On-Grid with Backup ^ Off-Grid Inrush Use ^ On-Grid ^ On-Grid with Backup ^ Off-Grid Inrush Use ^
 +| MultiPlus 48/3000/35 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥2|
 +| MultiPlus 48/5000/70 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥2|
 +| MultiPlus-II GX 48/3000/35-32 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| MultiPlus-II GX 48/5000/70-50 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥2|
 +| MultiPlus-II 230V 48/3000/35-32 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| MultiPlus-II 48/4k5/55-32 230V |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥3|
 +| MultiPlus-II 230V 48/5000/70-50 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥2|
 +| MultiPlus-II 48/6k5/100-50 230V |  ≥1|  ≥1|  ≥2|  ≥1|  ≥3|  ≥4|
 +| MultiPlus-II 230V 48/8000/110-100 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| MultiPlus-II 230V 48/10000/140-100 |  ≥1|  ≥2|  ≥2|  ≥1|  ≥5|  ≥5|
 +| MultiPlus-II 230V 48/15000/200-100 |  ≥1|  ≥2|  ≥2|  ≥1|  ≥6|  ≥6|
 +| MultiPlus-II 24/3000/70-32 GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| MultiPlus-II 48/3000/35-32 230V GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥2|
 +| MultiPlus-II 48/5000/70-50 230V GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| MultiPlus-II 48/4k5/55-32 230V GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥3|
 +| MultiPlus-II 48/6k5/100-50 230V GX |  ≥1|  ≥1|  ≥2|  ≥1|  ≥3|  ≥4|
 +| Multi RS Solar 48/6000 Dual Tracker |  ≥1|  ≥3|  ≥3|  ≥1|  ≥10|  ≥10|
 +| Quattro 48/5000/70-100/100 |  ≥1|  ≥2|  ≥2|  ≥1|  ≥2|  ≥3|
 +| Quattro 48/8000/110-100/100 |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| Quattro 48/10000/140-100/100 |  ≥1|  ≥2|  ≥2|  ≥1|  ≥5|  ≥5|
 +| Quattro 48/15000/200-100/100 |  ≥1|  ≥2|  ≥2|  ≥1|  ≥6|  ≥6|
 +| Quattro-II 48/5000/70-50 |  ≥1|  ≥3|  ≥3|  ≥1|  ≥10|  ≥10|
 +| EasySolar-II 48/3000/35-32 MPPT 250/70 GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥2|
 +| EasySolar-II 24/3000/70-32 MPPT 250/70 GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| EasySolar-II 48/5000/70-50 MPPT 250/100 GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥3|  ≥3|
 +| EasySolar-II 48/4k5/55-32 MPPT 250/70 GX |  ≥1|  ≥1|  ≥1|  ≥1|  ≥2|  ≥3|
 +| EasySolar-II 48/6k5/100-50 MPPT 250/100 GX |  ≥1|  ≥1|  ≥2|  ≥1|  ≥3|  ≥4|
 +| Battery firmware: BMS ≥1.2; GX firmware ≥V3.20 |||||||
  
  
Line 534: Line 571:
  
  
-===== DISQUS ===== +
-~~DISQUS~~+
battery_compatibility/byd_b-box.1759733027.txt.gz · Last modified: by guy_stewart

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki