battery_compatibility:byd_b-box
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| battery_compatibility:byd_b-box [2025-01-30 08:28] – [12. High voltage warning or alarm shown on battery status] guy_stewart | battery_compatibility:byd_b-box [2026-08-14 11:34] (current) – guy_stewart | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Victron & BYD ====== | ====== Victron & BYD ====== | ||
| - | ^ Battery ^ Pro 2.5-10.0 ^ Pro 12.8 & 13.8 ^ L 3.5-14.0 ^ Premium LVL 15.4 ^ Premium LVS 4.0 ^ LV Flex 5 ^ | ||
| - | | Appearance | {{ : | ||
| - | | ESS | yes| yes| yes| yes| yes| yes| | ||
| - | | Grid Backup| | ||
| - | | Off-Grid| | ||
| - | | Module capacity| | ||
| - | | Module limit | 32| 32| 12| 64| 64| 64| | ||
| - | | Max capacity| | ||
| ===== 1. Product & System compatibility ===== | ===== 1. Product & System compatibility ===== | ||
| Line 21: | Line 13: | ||
| For Off-grid systems, its strongly recommend to make sure there is a minimum of DC-Coupled PV (= MPPT Solar Charger) in the system. Ie. not only AC-Coupled PV. Also, minimum battery configuration, | For Off-grid systems, its strongly recommend to make sure there is a minimum of DC-Coupled PV (= MPPT Solar Charger) in the system. Ie. not only AC-Coupled PV. Also, minimum battery configuration, | ||
| + | |||
| + | |||
| + | ^ Battery ^ Pro 2.5-10.0 ^ Pro 12.8 & 13.8 ^ L 3.5-14.0 ^ Premium LVL 15.4 ^ Premium LVS 4.0 ^ LV Flex 5 ^ LV5.0+/ | ||
| + | | Appearance | {{ : | ||
| + | | ESS | yes| yes| yes| yes| yes| yes| yes| | ||
| + | | Grid Backup| | ||
| + | | Off-Grid| | ||
| + | | Module capacity| | ||
| + | | Module limit | 32| 32| 12| 64| 64| 64| 32| | ||
| + | | Max capacity| | ||
| + | |||
| === 1.2 A GX device is required, eg Cerbo GX, etc === | === 1.2 A GX device is required, eg Cerbo GX, etc === | ||
| Line 61: | Line 64: | ||
| | B-BOX Premium LVS 4.0 | | | B-BOX Premium LVS 4.0 | | ||
| | B-BOX LV Flex 5.0 | | | B-BOX LV Flex 5.0 | | ||
| + | | B-BOX LV5.0+/ | ||
| BYD also releases firmware update for their BMU and BMS. | BYD also releases firmware update for their BMU and BMS. | ||
| Line 179: | Line 183: | ||
| | | | | ||
| | | | | ||
| + | |||
| + | |||
| + | === Battery Modules Required - LV5.0+/ | ||
| + | ^ Inverter/ | ||
| + | ^ ::: ^ On-Grid ^ On-Grid with Backup ^ Off-Grid Inrush Use ^ On-Grid ^ On-Grid with Backup ^ Off-Grid Inrush Use ^ | ||
| + | | MultiPlus 48/3000/35 | ≥1| ≥1| ≥1| ≥1| ≥2| ≥2| | ||
| + | | MultiPlus 48/5000/70 | ≥1| ≥1| ≥1| ≥1| ≥2| ≥2| | ||
| + | | MultiPlus-II GX 48/ | ||
| + | | MultiPlus-II GX 48/ | ||
| + | | MultiPlus-II 230V 48/ | ||
| + | | MultiPlus-II 48/ | ||
| + | | MultiPlus-II 230V 48/ | ||
| + | | MultiPlus-II 48/ | ||
| + | | MultiPlus-II 230V 48/ | ||
| + | | MultiPlus-II 230V 48/ | ||
| + | | MultiPlus-II 230V 48/ | ||
| + | | MultiPlus-II 24/ | ||
| + | | MultiPlus-II 48/ | ||
| + | | MultiPlus-II 48/ | ||
| + | | MultiPlus-II 48/ | ||
| + | | MultiPlus-II 48/ | ||
| + | | Multi RS Solar 48/6000 Dual Tracker | ≥1| ≥3| ≥3| ≥1| ≥10| | ||
| + | | Quattro 48/ | ||
| + | | Quattro 48/ | ||
| + | | Quattro 48/ | ||
| + | | Quattro 48/ | ||
| + | | Quattro-II 48/ | ||
| + | | EasySolar-II 48/ | ||
| + | | EasySolar-II 24/ | ||
| + | | EasySolar-II 48/ | ||
| + | | EasySolar-II 48/ | ||
| + | | EasySolar-II 48/ | ||
| + | | Battery firmware: BMS ≥1.2; GX firmware ≥V3.20 ||||||| | ||