User Tools

Site Tools


assistants:overview_of_available_assistants

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
assistants:overview_of_available_assistants [2016-12-11 21:11] – [Self-consumption Hub-4] mvaderassistants:overview_of_available_assistants [2022-06-01 13:41] (current) – Fixed typo. fredhen
Line 10: Line 10:
 {{:assistants:ess-first-page.png?direct&150 }} {{:assistants:ess-first-page.png?direct&150 }}
  
-[[ess:start|]]+For Energy Storage Systems (ESS). The Assistant manages the prioritising of Solar Power.
  
-Only for hardware with new microprocessor (26 or 27).+[[ess:start|Documentation]].
  
-==== Self-consumption Hub-1 - for dc-coupled systems ====+==== PV Inverter support ==== 
 + 
 +{{:assistants:pvinvertersupport.png?direct&150 }} 
 + 
 +Use this Assistant in Off-grid systems that have AC-Coupled solar power: a grid-tie PV inverter connected to the AC out of a Multi or Quattro inverter/charger. 
 + 
 +[[:assistants:pv-inverter-support|Documentation]]. 
 + 
 + 
 + 
 +==== DEPRECATED Self-consumption Hub-1 - for dc-coupled systems ====
  
 {{:assistants:self-consumption-hub-1-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-1-policy.png?direct&150 }} {{:assistants:self-consumption-hub-1-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-1-policy.png?direct&150 }}
  
-[[:assistants:self_consumption_hub-1|Self-consumption hub-1 Assistant]].+Note that Hub-1 is deprecated in favor of [[ess:start|ESS]]. 
 + 
 +[[:assistants:self_consumption_hub-1|Hub-1 Assistant documentation]]
 + 
 +Hub-1 is only for hardware with new microprocessor (26 or 27)
  
-Only for hardware with new microprocessor (26 or 27). +[[assistants:hub1_and_hub2_notes|]]
  
-==== Self-consumption Hub-2 v3 - for ac-coupled systems ====+==== DEPRECATED Self-consumption Hub-2 v3 - for ac-coupled systems ====
  
 {{:assistants:self-consumption-hub-2-v3-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-2-v3-policy.png?direct&150 }}  {{:assistants:self-consumption-hub-2-v3-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-2-v3-policy.png?direct&150 }} 
Line 28: Line 42:
 Take note of the [[:ac_coupling:start|factor 1.0 rule]]. Take note of the [[:ac_coupling:start|factor 1.0 rule]].
  
-See also our [[https://www.victronenergy.com/blog/2014/07/29/self-consumption-hub-2-v3-assistant-a-major-update/|blog post on the Self-consumption Hub-2 Assistant]].+Deprecated in favor of [[ess:start|ESS]].
  
 Only for hardware with new microprocessor (26 or 27). Only for hardware with new microprocessor (26 or 27).
  
-==== Self-consumption Hub-2 v2 - for ac-coupled systems ====+[[assistants:hub1_and_hub2_notes|]] 
 + 
 +==== DEPRECATED Self-consumption Hub-2 v2 - for ac-coupled systems ====
  
 Use only on hardware with old microprocessor (19 or 20). On newer systems, use the version 3 instead, see above. Use only on hardware with old microprocessor (19 or 20). On newer systems, use the version 3 instead, see above.
Line 38: Line 54:
 Take note of the [[:ac_coupling:start|factor 1.0 rule]]. Take note of the [[:ac_coupling:start|factor 1.0 rule]].
  
-==== Self-consumption Hub-4 ====+Note that all Hub-2 Assistant versions have been deprecated in favor of [[ess:start|ESS]]. 
 + 
 +[[assistants:hub1_and_hub2_notes|]] 
 + 
 +==== DEPRECATED Self-consumption Hub-4 ====
  
 {{:assistants:self-consumption-hub-4-welcome.png?direct&150 |}} {{:assistants:self-consumption-hub-4-welcome.png?direct&150 |}}
Line 48: Line 68:
 Only for hardware with new microprocessor (26 or 27). Only for hardware with new microprocessor (26 or 27).
  
-==== PV Inverter support ==== 
- 
-{{:assistants:pvinvertersupport.png?direct&150 }} 
- 
-Used in: 
-  * Off-grid PV installs 
-  * Systems using the Hub-4 Assistant with a PV Inverter connected to the output of the Multi or Quattro. Note that Hub-4 has been deprecated: use [[ess:start|ESS]] instead. And PV Inverter Support / frequency shifting is built into ESS: no need to add the PV Inverter Support Assistant as well. 
- 
-Take note of the [[:ac_coupling:start|factor 1.0 rule]]. 
  
  
Line 63: Line 74:
 ==== Generator start and stop ==== ==== Generator start and stop ====
  
-{{:assistants:c000c5d0534684c578209f4e3445bef0.png?direct&150 }}Automatically start and stop a generator based on battery state of charge and actual load of a system. Note that automatic genset start/stop functionality is also available on the Virtual switch tab, which is easier to configure and does not require uploading another type of firmware. See the PDF [[https://www.victronenergy.com/upload/documents/manual-VE.Bus-firmware-versions-explained-EN.pdf|VE.Bus firmware versions explained]] for more information about the different firmware types.+{{:assistants:c000c5d0534684c578209f4e3445bef0.png?direct&150 }}Automatically start and stop a generator based on battery state of charge and actual load of a system. Note that automatic genset start/stop functionality is also available on the Virtual switch tab in VEConfigure, which is easier to work with. 
 + 
 +This is one of the available options to automatically start and stop a generator using Victron equipment. See the [[auto-generator-start-stop:start|]] document for an overview of all options. More general information about  using a generator in combination with Victron is available [[:multiplus_faq|here]].
  
 This Generator start and stop Assistant is also the one to use to [[:assistants:ignore_ac_input_using_the_generator_assistant|configure Ignore AC Input using Assistants]]. This Generator start and stop Assistant is also the one to use to [[:assistants:ignore_ac_input_using_the_generator_assistant|configure Ignore AC Input using Assistants]].
Line 69: Line 82:
 ==== AC Current sensor ==== ==== AC Current sensor ====
  
-{{:assistants:ac_current_sensor.png?direct&150 }}Reads PV Inverter current, using an AC Current sensor (CSE000100000), connected to a VE.Bus product. More information available in the [[https://www.victronenergy.com/upload/documents/Manual-AC-Current-sensor-EN.pdf|AC Current sensor manual]].+{{:assistants:ac_current_sensor.png?direct&150 }}Reads PV Inverter current, using an AC Current sensor (CSE000100000), connected to a VE.Bus product. More information available in the [[https://www.victronenergy.com/live/ac_current_sensor:start|AC Current sensor manual]].
  
 ==== Silence fan ==== ==== Silence fan ====
Line 91: Line 104:
 {{:assistants:85fa9bbfa1ab60f30e018fae30f2b3c2.png?direct&150 }}Used to wire an emergency stop button to a VE.Bus system. {{:assistants:85fa9bbfa1ab60f30e018fae30f2b3c2.png?direct&150 }}Used to wire an emergency stop button to a VE.Bus system.
  
-==== VE.Bus BMS support ====+==== DEPRECATED VE.Bus BMS support ====
  
-{{:assistants:d4c13a7dba68a0ac07ef946122785e57.png?direct&150 }}Required in combination with a [[https://www.victronenergy.com/batteries/lithium-battery-12,8v|VE.Bus BMS, used with our 12.8 V Lithium batteries]]. This Assistant communicates with the BMS and controls the Multi based on the BMS measurements.+{{:assistants:d4c13a7dba68a0ac07ef946122785e57.png?direct&150 }}
  
-==== Lynx Ion BMS support ====+Deprecated: per VE.Bus firmware version 489, this Assistant is no longer required. When installing a system with VE.Bus BMS, our advice is to first update the firmware of the inverter, using VictronConnect, and thereafter do the configuration. No Assistant needed.
  
-{{:assistants:020b6a4a7ba5fc55edf4bdf7307dd0ed.png?direct&150 }}Required in combination with a [[https://www.victronenergy.com/batteries/lithium-battery-24v-180ah|Lynx Ion BMS, used with our 24 V 180 Ah Lithium system]]. This Assistant can also be used to control the Multi with a third party Lithium system including BMS. See our PDF [[https://www.victronenergy.com/upload/documents/Manual-Connecting-other-lithium-battery-systems-to-Multis-and-Quattros-EN.pdf|Connecting other lithium battery systems to Multis and Quattros]] for more information.+Required in combination with a [[https://www.victronenergy.com/batteries/lithium-battery-12,8v|VE.Bus BMS, used with our 12.8 V Lithium batteries]]. This Assistant communicates with the BMS and controls the Multi based on the BMS measurements. 
 + 
 +==== Two-Signal BMS support (previously called Lynx Ion BMS support) ==== 
 + 
 +{{:assistants:020b6a4a7ba5fc55edf4bdf7307dd0ed.png?direct&150 }}Required in combination with a Lynx Ion BMS, used with our 24 V 180 Ah Lithium system. This Assistant can also be used to control the Multi with a third party Lithium system including BMS. See our PDF [[https://www.victronenergy.com/upload/documents/Manual-Connecting-other-lithium-battery-systems-to-Multis-and-Quattros-EN.pdf|Connecting other lithium battery systems to Multis and Quattros]] for more information.
  
  
Line 114: Line 131:
 {{:assistants:6e528aa50cd09a1740b2056370552464.png?direct&150 }} {{:assistants:6e528aa50cd09a1740b2056370552464.png?direct&150 }}
  
 +
 +===== DISQUS =====
 ~~DISQUS~~ ~~DISQUS~~
  
assistants/overview_of_available_assistants.1481487104.txt.gz · Last modified: 2016-12-11 21:11 by mvader

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki