User Tools

Site Tools


assistants:overview_of_available_assistants

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Last revisionBoth sides next revision
assistants:overview_of_available_assistants [2017-12-05 17:52] – [Lynx Ion BMS support] mvaderassistants:overview_of_available_assistants [2022-02-03 06:09] – [VE.Bus BMS support (Deprecated)] mvader
Line 10: Line 10:
 {{:assistants:ess-first-page.png?direct&150 }} {{:assistants:ess-first-page.png?direct&150 }}
  
-[[ess:start|]]+For Energy Storage Systems (ESS). The Assistant manages the prioritising of Solar Power.
  
-Only for hardware with new microprocessor (26 or 27).+[[ess:start|Documentation]].
  
-==== Self-consumption Hub-1 - for dc-coupled systems ====+==== PV Inverter support ==== 
 + 
 +{{:assistants:pvinvertersupport.png?direct&150 }} 
 + 
 +Use this Assistant in Off-grid systems that have AC-Coupled solar power: a grid-tie PV inverter connected to the AC out of a Multi or Quattro inverter/charger. 
 + 
 +[[:assistants:pv-inverter-support|Documentation]]. 
 + 
 + 
 + 
 +==== DEPRECATED Self-consumption Hub-1 - for dc-coupled systems ====
  
 {{:assistants:self-consumption-hub-1-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-1-policy.png?direct&150 }} {{:assistants:self-consumption-hub-1-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-1-policy.png?direct&150 }}
  
-[[:assistants:self_consumption_hub-1|Self-consumption hub-1 Assistant]].+Note that Hub-1 is deprecated in favor of [[ess:start|ESS]]. 
 + 
 +[[:assistants:self_consumption_hub-1|Hub-1 Assistant documentation]]
 + 
 +Hub-1 is only for hardware with new microprocessor (26 or 27)
  
-Only for hardware with new microprocessor (26 or 27). +[[assistants:hub1_and_hub2_notes|]]
  
-==== Self-consumption Hub-2 v3 - for ac-coupled systems ====+==== DEPRECATED Self-consumption Hub-2 v3 - for ac-coupled systems ====
  
 {{:assistants:self-consumption-hub-2-v3-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-2-v3-policy.png?direct&150 }}  {{:assistants:self-consumption-hub-2-v3-welcome.png?direct&150 }} {{:assistants:self-consumption-hub-2-v3-policy.png?direct&150 }} 
Line 28: Line 42:
 Take note of the [[:ac_coupling:start|factor 1.0 rule]]. Take note of the [[:ac_coupling:start|factor 1.0 rule]].
  
-See also our [[https://www.victronenergy.com/blog/2014/07/29/self-consumption-hub-2-v3-assistant-a-major-update/|blog post on the Self-consumption Hub-2 Assistant]].+Deprecated in favor of [[ess:start|ESS]].
  
 Only for hardware with new microprocessor (26 or 27). Only for hardware with new microprocessor (26 or 27).
  
-==== Self-consumption Hub-2 v2 - for ac-coupled systems ====+[[assistants:hub1_and_hub2_notes|]] 
 + 
 +==== DEPRECATED Self-consumption Hub-2 v2 - for ac-coupled systems ====
  
 Use only on hardware with old microprocessor (19 or 20). On newer systems, use the version 3 instead, see above. Use only on hardware with old microprocessor (19 or 20). On newer systems, use the version 3 instead, see above.
Line 38: Line 54:
 Take note of the [[:ac_coupling:start|factor 1.0 rule]]. Take note of the [[:ac_coupling:start|factor 1.0 rule]].
  
-==== Self-consumption Hub-4 ====+Note that all Hub-2 Assistant versions have been deprecated in favor of [[ess:start|ESS]]. 
 + 
 +[[assistants:hub1_and_hub2_notes|]] 
 + 
 +==== DEPRECATED Self-consumption Hub-4 ====
  
 {{:assistants:self-consumption-hub-4-welcome.png?direct&150 |}} {{:assistants:self-consumption-hub-4-welcome.png?direct&150 |}}
Line 47: Line 67:
  
 Only for hardware with new microprocessor (26 or 27). Only for hardware with new microprocessor (26 or 27).
- 
-==== PV Inverter support ==== 
- 
-{{:assistants:pvinvertersupport.png?direct&150 }} 
- 
-Used in Off-grid PV installs with a grid-tie PV inverter connected to the AC out of a Multi or Quattro. 
- 
-This Assistant will be idle when the Multi or Quattro is connected to mains. 
- 
-When the system is in inverter mode, this Assistant controls the output power of the grid-tie inverter by changing the AC output frequency of the system. It then regulates the charge process: preventing overcharging the batteries. 
- 
-Take note of the [[:ac_coupling:start|factor 1.0 rule]]. 
- 
-[[:assistants:three_phase_pv_inverter_assistant|Setting up PV Inverter Support on a three-phase 2xx installation]] 
  
  
Line 68: Line 74:
 ==== Generator start and stop ==== ==== Generator start and stop ====
  
-{{:assistants:c000c5d0534684c578209f4e3445bef0.png?direct&150 }}Automatically start and stop a generator based on battery state of charge and actual load of a system. Note that automatic genset start/stop functionality is also available on the Virtual switch tab, which is easier to configure and does not require uploading another type of firmware. See the PDF [[https://www.victronenergy.com/upload/documents/manual-VE.Bus-firmware-versions-explained-EN.pdf|VE.Bus firmware versions explained]] for more information about the different firmware types.+{{:assistants:c000c5d0534684c578209f4e3445bef0.png?direct&150 }}Automatically start and stop a generator based on battery state of charge and actual load of a system. Note that automatic genset start/stop functionality is also available on the Virtual switch tab in VEConfigure, which is easier to work with. 
 + 
 +This is one of the available options to automatically start and stop a generator using Victron equipment. See the [[auto-generator-start-stop:start|]] document for an overview of all options. More general information about  using a generator in combination with Victron is available [[:multiplus_faq|here]].
  
 This Generator start and stop Assistant is also the one to use to [[:assistants:ignore_ac_input_using_the_generator_assistant|configure Ignore AC Input using Assistants]]. This Generator start and stop Assistant is also the one to use to [[:assistants:ignore_ac_input_using_the_generator_assistant|configure Ignore AC Input using Assistants]].
Line 74: Line 82:
 ==== AC Current sensor ==== ==== AC Current sensor ====
  
-{{:assistants:ac_current_sensor.png?direct&150 }}Reads PV Inverter current, using an AC Current sensor (CSE000100000), connected to a VE.Bus product. More information available in the [[https://www.victronenergy.com/upload/documents/Manual-AC-Current-sensor-EN.pdf|AC Current sensor manual]].+{{:assistants:ac_current_sensor.png?direct&150 }}Reads PV Inverter current, using an AC Current sensor (CSE000100000), connected to a VE.Bus product. More information available in the [[https://www.victronenergy.com/live/ac_current_sensor:start|AC Current sensor manual]].
  
 ==== Silence fan ==== ==== Silence fan ====
Line 96: Line 104:
 {{:assistants:85fa9bbfa1ab60f30e018fae30f2b3c2.png?direct&150 }}Used to wire an emergency stop button to a VE.Bus system. {{:assistants:85fa9bbfa1ab60f30e018fae30f2b3c2.png?direct&150 }}Used to wire an emergency stop button to a VE.Bus system.
  
-==== VE.Bus BMS support ====+==== DELRECATED VE.Bus BMS support ====
  
-{{:assistants:d4c13a7dba68a0ac07ef946122785e57.png?direct&150 }}Required in combination with a [[https://www.victronenergy.com/batteries/lithium-battery-12,8v|VE.Bus BMS, used with our 12.8 V Lithium batteries]]. This Assistant communicates with the BMS and controls the Multi based on the BMS measurements.+{{:assistants:d4c13a7dba68a0ac07ef946122785e57.png?direct&150 }} 
 + 
 +Deprecated: per VE.Bus firmware version 489, this Assistant is no longer required. When installing a system with VE.Bus BMS, our advice is to first update the firmware of the inverter, using VictronConnect, and thereafter do the configuration. No Assistant needed. 
 + 
 +Required in combination with a [[https://www.victronenergy.com/batteries/lithium-battery-12,8v|VE.Bus BMS, used with our 12.8 V Lithium batteries]]. This Assistant communicates with the BMS and controls the Multi based on the BMS measurements.
  
 ==== Two-Signal BMS support (previously called Lynx Ion BMS support) ==== ==== Two-Signal BMS support (previously called Lynx Ion BMS support) ====
  
-{{:assistants:020b6a4a7ba5fc55edf4bdf7307dd0ed.png?direct&150 }}Required in combination with a [[https://www.victronenergy.com/batteries/lithium-battery-24v-180ah|Lynx Ion BMS, used with our 24 V 180 Ah Lithium system]]. This Assistant can also be used to control the Multi with a third party Lithium system including BMS. See our PDF [[https://www.victronenergy.com/upload/documents/Manual-Connecting-other-lithium-battery-systems-to-Multis-and-Quattros-EN.pdf|Connecting other lithium battery systems to Multis and Quattros]] for more information.+{{:assistants:020b6a4a7ba5fc55edf4bdf7307dd0ed.png?direct&150 }}Required in combination with a Lynx Ion BMS, used with our 24 V 180 Ah Lithium system. This Assistant can also be used to control the Multi with a third party Lithium system including BMS. See our PDF [[https://www.victronenergy.com/upload/documents/Manual-Connecting-other-lithium-battery-systems-to-Multis-and-Quattros-EN.pdf|Connecting other lithium battery systems to Multis and Quattros]] for more information.
  
  
Line 119: Line 131:
 {{:assistants:6e528aa50cd09a1740b2056370552464.png?direct&150 }} {{:assistants:6e528aa50cd09a1740b2056370552464.png?direct&150 }}
  
 +
 +===== DISQUS =====
 ~~DISQUS~~ ~~DISQUS~~
  
assistants/overview_of_available_assistants.txt · Last modified: 2022-06-01 13:41 by fredhen

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki