ac_current_sensor:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
ac_current_sensor:start [2018-11-30 10:38] – mvader | ac_current_sensor:start [2018-12-06 14:52] – guy_stewart | ||
---|---|---|---|
Line 4: | Line 4: | ||
{{ : | {{ : | ||
==== Introduction ==== | ==== Introduction ==== | ||
- | The AC Current sensor is a simple external current sensor | + | |
+ | Use the AC Current | ||
+ | |||
+ | The sensor is a simple external current sensor, which measures | ||
+ | |||
+ | The AC Current Sensor is one out of multiple options to visualise the solar yield in a Victron system. See [[ccgx: | ||
+ | |||
+ | |||
+ | ==== Specifications ==== | ||
+ | |||
+ | ^Power range ^ | ||
+ | |Power step size Approx depends on input voltage (230V AC) | 9 | 17 | 30 | 35 | W | | ||
+ | |Power step size Approx depends on input voltage (120V AC) | 4.5 | 8.5 | 15 | 17.5 | W | | ||
+ | |Max measured Current | 8 | 16 | 25 | 30.5 | A | | ||
+ | |Max Input current | | ||
+ | |Dipswitch | all off | 1 | 1,2 | 1,2,3 | | | ||
+ | |Max # of sensors in one system | ||
+ | |Protection category | | ||
==== Multi and Quattro hardware requirements ==== | ==== Multi and Quattro hardware requirements ==== | ||
Line 10: | Line 27: | ||
- The TEMP-sense input of all Multi’s and Quattro’s is suitable for the AC Current Sensor. | - The TEMP-sense input of all Multi’s and Quattro’s is suitable for the AC Current Sensor. | ||
- The AUX-input however is not, see serial number list below to check your hardware. | - The AUX-input however is not, see serial number list below to check your hardware. | ||
- | - On the Multiplus-II hardware revision 0 to 8, the AUX input is on the RJ12 connector, pin 1 and 5. Refer to appendix A of the manual. In later revisions the AUX input is available as a normal terminal again. | + | - The Multi or Quattro needs to be connected on the VE.Bus port of the Color Control GX: readout will __not__ work when connected on the VE.Can port using a [[https:// |
- | - the Multi or Quattro needs to be connected on the VE.Bus port of the Color Control GX: readout will __not__ work when connected on the VE.Can port using a [[https:// | + | |
+ | - On the Multiplus-II hardware revision 0 to 8, the AUX input is on the RJ12 connector, pin 1 and 5. Refer to appendix A of the Multiplus-II manual. In later revisions the AUX input is available as a normal terminal again. | ||
+ | - This AC Current sensor (CSE000100000) should not be confused with the specific Current Transformer 100A:50mA accessory for MultiPlus-II (part number CTR110000500). | ||
==== Installation ==== | ==== Installation ==== | ||
{{ : | {{ : | ||
- | - Put one of the AC wires of the PV inverter through the AC Current sensor. | + | - Pull one of the AC wires of the PV inverter through the AC Current sensor. |
- Connect the sensor to the AUX or TEMP-sense input of an Inverter, Multi or Quattro in the same phase as being measured by that current sensor. | - Connect the sensor to the AUX or TEMP-sense input of an Inverter, Multi or Quattro in the same phase as being measured by that current sensor. | ||
- Configure the power range with the dipswitches. Select the power equal or higher than the maximum expected power. For example, with a 4kW PV installation, | - Configure the power range with the dipswitches. Select the power equal or higher than the maximum expected power. For example, with a 4kW PV installation, | ||
Line 22: | Line 41: | ||
==== Configuration ==== | ==== Configuration ==== | ||
- | - Upgrade | + | - Make sure the firmware |
- Parallel and three-phase systems: configure parallel or three-phase operation first. | - Parallel and three-phase systems: configure parallel or three-phase operation first. | ||
- Then use the VEConfigure3 to add and configure the 'AC Current sensor’ assistant. | - Then use the VEConfigure3 to add and configure the 'AC Current sensor’ assistant. | ||
- Parallel and three-phase systems: add the assistant to each Multi or Quattro that has an AC Current sensor connected to it. | - Parallel and three-phase systems: add the assistant to each Multi or Quattro that has an AC Current sensor connected to it. | ||
- | - Make sure that the Color Control | + | - Whilst |
- | - Select the correct profile on the Color Control: Settings -> System setup. | + | - Select the correct profile on the [[venus-os: |
- | ==== FAQ ==== | + | ==== Compatibility list ==== |
- | ===How many AC Current Sensors can I connect in one VE.Bus system? | + | |
- | The current maximum is four sensors. Note that each need to be configured separately with an assistant in the Multi or Quattro to which it is wired. The maximum of four will be increased to 9, in CCGX version v1.30, planned for December 2015 | + | |
- | \\ | ||
- | ==Specification== | ||
- | ^Power range ^1.5kW ^3kW ^5kW ^7kW ^Not used^^ | ||
- | |Power step size Approx depends on input voltage (230V AC) |9 |17 |30 |35 |- |W| | ||
- | |Power step size Approx depends on input voltage (120V AC) |4.5 |8.5 |15 |17.5 |- |W| | ||
- | |Max measured Current |8 |16 |25 |30.5 |- |A| | ||
- | |Max Input current |9 |18 |30 |40 |- |A| | ||
- | |Dipswitch |- |1 |1, | ||
- | |Protection category |IP54|||||| | ||
- | \\ | ||
- | \\ | ||
^Supported models ^^AUX input ^TEMP input ^ | ^Supported models ^^AUX input ^TEMP input ^ | ||
^Product code ^Description ^Minimum SN# | ^Product code ^Description ^Minimum SN# | ||
Line 73: | Line 79: | ||
|PMP485021014 |Multi-G 48/ | |PMP485021014 |Multi-G 48/ | ||
|_|||| | |_|||| | ||
- | |Other models ||Not yet implemented. |All serial numbers| | + | |Other models ||All serial numbers |All serial numbers| |