Skip to main content

Smart BatteryProtect 12/24V

Programming via VictronConnect app

Programming via VictronConnect app

Requirements prior to programming::

  1. The battery positive must be connected to the IN terminal. Do not connect the OUT terminal yet.

  2. The included ground wire must be connected to the battery minus and the GND terminal of the Smart BatteryProtect.

Programming procedure:

  1. Open the VictronConnect app on your mobile device.

    All available Bluetooth devices are displayed.

  2. Select the Smart BatteryProtect from the Device list and tap on it.

    This will open the status screen, showing battery and load output state.

  3. Tap on the cog wheel in the top right corner.

  4. Check whether the detected battery voltage matches the system voltage.

  5. Select the operation mode (A, B or C - see the Programming table and Operation modes for details).

    In case of C (Li-ion), nothing further needs to be set.

  6. Choose between Relay and Buzzer/LED to set the alarm output.

  7. Set the preset to the desired combination of shutdown and restart voltage or tap on User defined to define a custom combination.

  8. In case of a user defined preset, tap on Shut down to set the shutdown voltage and tap on Restart to set the restart voltage.

  9. Click on the 3 dots in the top right corner and then on Product info.

  10. In the Product info menu the PIN code can be changed, a custom name can be set and Bluetooth can be disabled.

Note