Skip to main content

Lynx Shunt VE.Can

4. Communication and interfacing

In this section:

4.1. GX Device

The Lynx Smart BMS can be connected to a GX device via VE.Can. The GX device will show all measured parameters, operational state, battery SoC and alarms.

4.2. NMEA2000

Communication with a NMEA2000 network can be established via the Lynx Shunt VE.Can VE.Can connection together with a VE.Can to NMEA2000 micro-C male cable.

Supported NMEA 2000 PGNs:

Product Information – PGN 126996

DC detailed Status – PGN 127506

DC/Battery Status – PGN 127508

Switch Bank Status - PGN 127501

  • Status 1: Contactor

  • Status 2: Alarm

  • Status 3: Battery voltage low

  • Status 4: Battery voltage high

  • Status 5: Programmable relay status

Class and function:

N2K device class: Electrical generation

N2K device function : Battery

For more information see the NMEA2000 & MFD integration guide.