vrm_portal:remote-veconfigure
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
vrm_portal:remote-veconfigure [2017-11-24 15:33] – created mvader | vrm_portal:remote-veconfigure [2023-05-15 14:18] (current) – mvader | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== VRM: Remote VEConfigure | + | ====== VRM: Remote VEConfigure ====== |
===== 1. Introduction ===== | ===== 1. Introduction ===== | ||
- | This manual describes how to remotely change settings in VE.Bus | + | This manual describes how to remotely change settings in our MultiPlusses, |
- | This functionality requires the device to be updated connected to a Venus device (CCGX, Venus GX, or other). | + | ===== 2. Requirements and limitations ===== |
- | This (new) way of Remote VEConfigure replaces the previous mechanism, that used VE.Power Setup. See [[ccgx:ccgx_ve_power_setup|here]] for the manual of the old procedure. Note that, once updated to the new Venus version, it is no longer possible | + | This functionality requires a [[venus-os:start|GX device]] (Cerbo GX, or other) |
Requirements: | Requirements: | ||
- | | + | |
- | | + | |
+ | - Two way communication must be enabled | ||
+ | - The [[venus-os: | ||
+ | - [[https:// | ||
Details: | Details: | ||
Line 17: | Line 20: | ||
* Remotely changing Assistant configuration is possible. | * Remotely changing Assistant configuration is possible. | ||
* VE.Bus firmware versions 416 and 417 can not be configured remotely | * VE.Bus firmware versions 416 and 417 can not be configured remotely | ||
- | * Remote configuring firmware version 418 or later requires the CCGX or Venus GX to run v2.10 or later | + | * Remote configuring firmware version 418 or later requires the GX device |
- | * To Remote VEConfigure a system connected to the CCGX via a VE.Bus to VE.Can interface, as was done in old Hub-1 systems, this interface cable needs to run firmware version v2.05 or higher. Note that it is possible to first update firmware | + | * To Remote VEConfigure a system connected to the GX device |
+ | * This (new) way of Remote VEConfigure replaces the previous mechanism, that used VE.Power Setup. See [[ccgx: | ||
+ | * The system protects against accidentally sending settings from one system to another. To that purpose, it will compare the serial numbers of the installed inverter/ | ||
+ | * For systems consisting of multiple inverter/ | ||
- | ===== 2. Procedure ===== | + | In some cases the VE.Bus system will momentarily switched off when changing the configuration. |
- | === Step 1. Go to Remote VEConfigure on the VRM Portal | + | ===== 3. Step by step procedure ===== |
- | FIXME add screenshot once last changes have been done. | + | {{youtube> |
- | === Step 2. Download | + | - Check the requirements |
+ | - Venus OS v2.17 or later | ||
+ | - Two way communication enabled (see Settings -> VRM Online Portal on the [[venus-os: | ||
+ | - Two way communication up & running: check on the Device list page on VRM | ||
+ | - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal | ||
+ | - Click the button and wait | ||
+ | - the system starts with reading all the settings of each inverter/ | ||
+ | - once all data has been gathered; its compiled into a file and uploaded | ||
+ | - Download/ | ||
+ | - Modify the configuration by opening the downloaded .RSVC file in VEConfigure. | ||
+ | - Save the file using the Close button in VEConfigure on the upper right. You will be asked if you wish to save the changes. Changes can be saved to both the .RVSC file, and also to another seperate .VSC file. | ||
+ | - Be Aware - You can only upload the .RVSC file when using Remote VEConfigure. If the file is saved via the File, Save As menu, instead of closing VEConfigure and confirming the changes, it will save to a new .VSC file. This file can be opened, adjusted, and used to update locally with an MK3 adapter, but it cannot be uploaded to update a remote unit. You must use the .RVSC file downloaded from the system that you intend to change the settings of, and then upload that same file once changes are made. | ||
+ | - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal | ||
+ | - Click the button and wait | ||
+ | - Click the Upload button, select the .RVSC file, and OK to send it to the system via the VRM | ||
- | {{ : | + | ===== 4. System shutdown during reconfiguration ===== |
- | === Step 3. Modify | + | Many settings can be changed without resulting in a shutdown during |
+ | {{ : | ||
- | {{ :vrm_portal: | + | known issue: Venus versions v2.23 and below always reset the Multi when the following settings are changed. |
+ | - Battery Capacity | ||
+ | - Start and stop limits for low power AES mode | ||
+ | - State of charge when Bulk finished (only resets with Multi firmware versions < 200) | ||
- | === Step 4. Upload | + | Depending on how the internet communication equipment (ie. router) is powered, |
- | ===== 3. Trouble shooting ===== | + | This is not a problem, as the file is first uploaded to the [[venus-os: |
- | + | ||
- | FIXME | + | |
- | + | ||
- | ===== 4. Disqus ===== | + | |
- | + | ||
- | ~~DISQUS~~ | + |
vrm_portal/remote-veconfigure.1511533990.txt.gz · Last modified: 2017-11-24 15:33 by mvader