vrm_portal:remote-veconfigure [2019-10-23 22:44] – guy_stewart | vrm_portal:remote-veconfigure [2020-12-05 12:17] – [3. Step by step procedure] guy_stewart | ||
---|---|---|---|
Line 4: | Line 4: | ||
This manual describes how to remotely change settings in our MultiPlusses, | This manual describes how to remotely change settings in our MultiPlusses, | ||
+ | |||
+ | ===== 2. Requirements and limitations ===== | ||
This functionality requires a [[venus-os: | This functionality requires a [[venus-os: | ||
Requirements: | Requirements: | ||
- | - Venus OS v2.17 or later | + | - A GX Device running |
- System must connected to internet and communicating to the VRM Portal. | - System must connected to internet and communicating to the VRM Portal. | ||
- Two way communication must be enabled | - Two way communication must be enabled | ||
Line 22: | Line 24: | ||
* This (new) way of Remote VEConfigure replaces the previous mechanism, that used VE.Power Setup. See [[ccgx: | * This (new) way of Remote VEConfigure replaces the previous mechanism, that used VE.Power Setup. See [[ccgx: | ||
- | In some cases the VE.Bus system will momentarily switched off when changing the configuration. See step 4 for more details. | + | In some cases the VE.Bus system will momentarily switched off when changing the configuration. |
- | ===== 2. Step by step procedure ===== | + | ===== 3. Step by step procedure ===== |
{{youtube> | {{youtube> | ||
Line 36: | Line 38: | ||
- the system starts with reading all the settings of each inverter/ | - the system starts with reading all the settings of each inverter/ | ||
- once all data has been gathered; its compiled into a file and uploaded to your computer. | - once all data has been gathered; its compiled into a file and uploaded to your computer. | ||
- | - Download the file to your computer | + | - Download the .RSVC file to your computer |
- | - Modify the configuration, save the file using the Close button in VEConfigure on the upport | + | - Modify the configuration. |
- | - Upload the file to the system | + | - Save the file using the Close button in VEConfigure on the upper right. |
+ | - Be Aware - You can only upload the .RVSC file when using Remote VEConfigure. If the file is saved via the File, Save As menu, instead of closing VEConfigure and confirming the changes, it will save to a new .VSC file. This file can be opened, adjusted, and used to update locally with an MK3 adapter, but it cannot be uploaded to update a remote unit. You must use the .RVSC file downloaded from the system that you intend to change the settings of, and then upload that same file once changes are made. | ||
+ | - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal | ||
+ | - Click the button and wait | ||
+ | - Click the Upload | ||
- | ===== 3. System shutdown during reconfiguration ===== | + | ===== 4. System shutdown during reconfiguration ===== |
Many settings can be changed without resulting in a shutdown during the re-configuration. Some settings though, such as a changed Assistants configuration, | Many settings can be changed without resulting in a shutdown during the re-configuration. Some settings though, such as a changed Assistants configuration, |
vrm_portal/remote-veconfigure.txt · Last modified: 2023-05-15 14:18 by mvader