Next revisionBoth sides next revision
vrm_portal:remote-veconfigure [2019-03-25 12:07] – [3. System shutdown during reconfiguration] Added reset issue jpasopvrm_portal:remote-veconfigure [2019-10-23 22:44] guy_stewart
Line 5: Line 5:
 This manual describes how to remotely change settings in our MultiPlusses, MultiGrid, MultiPlus-II, Quattros and high power Inverters; all power products with a VE.Bus communication port. A feature called ''Remote VEConfigure'' This manual describes how to remotely change settings in our MultiPlusses, MultiGrid, MultiPlus-II, Quattros and high power Inverters; all power products with a VE.Bus communication port. A feature called ''Remote VEConfigure''
  
-This functionality requires a [[venus-os:start|Venus-device]] (CCGX, Venus GX or other) to be installed locally on the system.+This functionality requires a [[venus-os:start|GX device]] (CCGX, Venus GX or other) to be installed locally on the system.
  
 Requirements: Requirements:
Line 11: Line 11:
   - System must connected to internet and communicating to the VRM Portal.   - System must connected to internet and communicating to the VRM Portal.
   - Two way communication must be enabled   - Two way communication must be enabled
-  - The [[venus-os:start|Venus-device]] must be powered directly from the battery. So do not power it an AC adapter on the AC output of the inverter/charger.+  - The [[venus-os:start|GX device]] must be powered directly from the battery. So do not power it an AC adapter on the AC output of the inverter/charger. 
 +  - [[https://docs.victronenergy.com/veconfigure.html|VEConfigure]]
  
 Details: Details:
Line 29: Line 30:
   - Check the requirements   - Check the requirements
     - Venus OS v2.17 or later     - Venus OS v2.17 or later
-    - Two way communication enabled (see Settings -> Services on the [[venus-os:start|Venus-device]])+    - Two way communication enabled (see Settings -> Services on the [[venus-os:start|GX device]])
     - Two way communication up & running: check on the Device list page on VRM     - Two way communication up & running: check on the Device list page on VRM
   - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal   - On the VRM Portal, go to Device List, and scroll to the bottom to find the Remote VEConfigure button on the VRM Portal
Line 51: Line 52:
 Depending on how the internet communication equipment (ie. router) is powered, the internet connection might also be temporarily lost at that time. Depending on how the internet communication equipment (ie. router) is powered, the internet connection might also be temporarily lost at that time.
  
-This is not a problem, as the file is first uploaded to the [[venus-os:start|Venus-device]], and only once received and verified it will be written to the VE.Bus system. +This is not a problem, as the file is first uploaded to the [[venus-os:start|GX device]], and only once received and verified it will be written to the VE.Bus system.
vrm_portal/remote-veconfigure.txt · Last modified: 2023-05-15 14:18 by mvader