User Tools

Site Tools


vrm_portal:remote-veconfigure

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revisionBoth sides next revision
vrm_portal:remote-veconfigure [2019-03-11 09:29] mvadervrm_portal:remote-veconfigure [2019-03-25 12:07] – [3. System shutdown during reconfiguration] Added reset issue jpasop
Line 43: Line 43:
 Many settings can be changed without resulting in a shutdown during the re-configuration. Some settings though, such as a changed Assistants configuration, will cause the inverter/charger to momentarily switch off and back on again. In such situations, VEConfig will warn when saving the settings: Many settings can be changed without resulting in a shutdown during the re-configuration. Some settings though, such as a changed Assistants configuration, will cause the inverter/charger to momentarily switch off and back on again. In such situations, VEConfig will warn when saving the settings:
 {{ :ccgx:remote-veconfig-vebus-reset-warning.png?nolink |}} {{ :ccgx:remote-veconfig-vebus-reset-warning.png?nolink |}}
 +
 +known issue: Venus versions v2.23 and below always reset the Multi when the following settings are changed.
 +  - Battery Capacity
 +  - Start and stop limits for low power AES mode
 +  - State of charge when Bulk finished (only resets with Multi firmware versions < 200)
  
 Depending on how the internet communication equipment (ie. router) is powered, the internet connection might also be temporarily lost at that time. Depending on how the internet communication equipment (ie. router) is powered, the internet connection might also be temporarily lost at that time.