User Tools

Site Tools


vrm_portal:remote-firmware-update

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
vrm_portal:remote-firmware-update [2018-11-13 05:35] – [2.6 Limitations] mvadervrm_portal:remote-firmware-update [2023-10-10 11:43] (current) – [2.2 Compatible products] sloges
Line 3: Line 3:
 ===== 1. Introduction ===== ===== 1. Introduction =====
  
-This manual describes how to remotely update firmware. This functionality requires the device to be updated connected to a Venus-device (CCGX, Venus GX, or other).+This manual describes how to remotely update firmware. This functionality requires the device to be updated connected to a [[venus-os:start|GX device]] (Cerbo GX, or other).
  
 Features: Features:
Line 10: Line 10:
   - Works from laptop, tablet & phone   - Works from laptop, tablet & phone
   - No need to find the right firmware file: the system has all, and will clearly indicate that a newer version is available.   - No need to find the right firmware file: the system has all, and will clearly indicate that a newer version is available.
-  - Works with VE.Direct products: MPPT Solar ChargersBMV Battery Monitor, Phoenix Inverters, and more. +  - For supported products, see below
-  - Works with VE.Can products: MPPT VE.Can Solar Chargers, Skylla-i, and more. +
- +
-.+
  
 +Demonstration video:
 {{youtube>oKvUXLUK1aM?medium}} {{youtube>oKvUXLUK1aM?medium}}
  
Line 20: Line 18:
  
 ==== 2.1 Requirements ==== ==== 2.1 Requirements ====
-  * Venus OS v2.17 or later+  * GX device must be running Venus OS v2.17 or later
   * System must be connected to the internet and communicating to the [[https://vrm.victronenergy.com|VRM Portal]].   * System must be connected to the internet and communicating to the [[https://vrm.victronenergy.com|VRM Portal]].
-  * The ''Two way communication'' setting, which is on the Venus-device, must be enabled.+  * The ''Two way communication'' setting, which is on the [[venus-os:start|GX device]] menu -> Settings -> Services (or VRM online portal), must be enabled.
  
 ==== 2.2 Compatible products ==== ==== 2.2 Compatible products ====
Line 28: Line 26:
  
 Products connected via VE.Direct communication port: Products connected via VE.Direct communication port:
-  * MPPT Solar Charge Controllers (1)+  * MPPT Solar Charge Controllers, including MPPT RS (See note below)
   * BMV Battery Monitors   * BMV Battery Monitors
-  * Phoenix Inverters+  * SmartShunts 
 +  * Inverter VE.Direct 
 +  * Smart IP43 Charger
  
 Products connected via VE.Can communication port: Products connected via VE.Can communication port:
   * MPPT Solar Charge Controllers   * MPPT Solar Charge Controllers
   * Skylla-i battery chargers   * Skylla-i battery chargers
 +  * Inverter RS, Multi RS and MPPT RS
 +  * Lynx Smart BMS
  
 +Victron Energy Multis, Quattros, other VE.Bus-connected Inverter/chargers and the VE.Bus BMS V2 can be updated as well; see [[https://www.victronenergy.com/live/venus-os:remote_ve.bus_firmware_updates|these instructions]].
 ==== 2.3 How does it work? ==== ==== 2.3 How does it work? ====
  
   - The new firmware file is first uploaded to the system.   - The new firmware file is first uploaded to the system.
-  - Once received and verified, the Venus-device starts updating the firmware of the connected device. This eliminates any problems that could be caused by an intermittent internet connection. In case the internet does break while performing the update, the system will continue with the firmware update.+  - Once received and verified, the [[venus-os:start|GX device]] starts updating the firmware of the connected device. This eliminates any problems that could be caused by an intermittent internet connection. In case the internet does break while performing the update, the system will continue with the firmware update.
  
 ==== 2.4 Where to find the firmware file? ==== ==== 2.4 Where to find the firmware file? ====
Line 67: Line 69:
 Updating firmware on a BMV that is connected via a [[https://www.victronenergy.com/accessories/ve-direct-to-ve-can-interface|canbus interface]] is not possible. Updating firmware on a BMV that is connected via a [[https://www.victronenergy.com/accessories/ve-direct-to-ve-can-interface|canbus interface]] is not possible.
  
-=== VE.Bus Products (Multis, Quattros, high power Inverters) === +=== Lynx Ion BMS Series === 
-Remotely updating firmware in VE.Bus products (Inverters, Multis and Quattros) is not possible and will also not become possible. +(note that this does not apply to the Lynx Smart BMS)
- +
-=== Lynx BMS Series ===+
  
 Remotely updating firmware of these Lynx series of products is not possible: Remotely updating firmware of these Lynx series of products is not possible:
Line 77: Line 77:
  
 Remote updating the Lynx Ion BMS 150A, 400A, 600A and 1000A model is possible. Notes: Remote updating the Lynx Ion BMS 150A, 400A, 600A and 1000A model is possible. Notes:
-  * The firmware library does not have the files. Download the file from [[https://professional.victronenergy.com|Victron Professional]] and use the option to self upload a file. +  * The firmware library does not always have the files. Download the file from [[https://professional.victronenergy.com|Victron Professional]] and use the option to self upload a file. 
-  * Make sure that the Venus-device is powered on the ''Aux-power output''. That is the only port that will remain powered during the firmware update process. All others (main contactor, and also Allow-to-charge and Allow-to-discharge signals) will disconnect; causing Multis and also loads to switch off. Once the update is completed, the Lynx BMS will restart and restore everything. +  * Make sure that the [[venus-os:start|GX device]] is powered on the ''Aux-power output''. That is the only port that will remain powered during the firmware update process. All others (main contactor, and also Allow-to-charge and Allow-to-discharge signals) will disconnect; causing Multis and also loads to switch off. Once the update is completed, the Lynx BMS will restart and restore everything. 
-  * In case the update fails, it can be retried; just like all other products. But in case of the Lynx BMS, this has to be done within 5 minutes. Otherwise it will will go to sleep mode and a push on the start button is required.+  * In case the update fails, it can be retried; just like all other products. But in case of the Lynx BMS, this has to be done within 5 minutes. Otherwise it will go to sleep mode and a push on the start button is required.
  
  
Line 86: Line 86:
 ===== 3. Step by step instructions ===== ===== 3. Step by step instructions =====
  
-==== Step 1. Go to Firmware updates on the VRM Portal ====+=== Step 1. Go to Firmware updates on the VRM Portal ===
  
 {{ :vrm_portal:vrm_fw_updates_list.png?direct&600 |}} {{ :vrm_portal:vrm_fw_updates_list.png?direct&600 |}}
  
-There, any device for which a new firmware version is available will show a green Update button. Press that button to initiate the update.+There, any device for which a new firmware version is available will show a green Update button. Press that button to initiate the update. N.B. the location for this facility has move to the bottom of the Device List, as per the earlier video.
  
-==== Step 2. Update process ====+=== Step 2. Update process ===
  
 {{ :vrm_portal:vrm_fw_update_updating.png?direct&600 |}} {{ :vrm_portal:vrm_fw_update_updating.png?direct&600 |}}
  
-==== Step 3. Finished ====+=== Step 3. Finished ===
  
 {{ :vrm_portal:vrm_fw_update_complete.png?direct&600 |}} {{ :vrm_portal:vrm_fw_update_complete.png?direct&600 |}}
  
 +===== 4. Uploading a firmware file ====
  
-===== 4Trouble shooting =====+In most situations the system will already have a firmware file available; no need to upload anything yourself. Sometimes however it is necessary to upload a file from your computer; and this chapter explains how that's done.
  
-=== Error  1341 Not updatable ===+First start with having the system list the updatable devices; the result will look like this:
  
-Typically shows when it is not a Victron product.+{{ :vrm_portal:vrm-list2.png?nolink }}
  
-=== Error 1342 Not updatable ===+Click the three dots  on the right of a line; the upload file button will show.
  
-Updatable not true as returned by the device/vup/dup.+Click that, select the file on your computer; and the rest of the procedure will continue as explained above. 
 + 
 +===== 5. Trouble shooting ===== 
 + 
 +=== Error  1341 Not updatable === 
 + 
 +Typically shows when it is not a Victron product.
  
 === Error 1343 Not updatable: Blacklisted === === Error 1343 Not updatable: Blacklisted ===
  
 See limitations chapter above. The product you are trying to update cannot be updated remotely. See limitations chapter above. The product you are trying to update cannot be updated remotely.
vrm_portal/remote-firmware-update.1542083751.txt.gz · Last modified: 2018-11-13 05:35 by mvader

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki