victronconnect:mppt-solarchargers [2020-06-23 09:18] – [4.1 Battery settings] tabreuvictronconnect:mppt-solarchargers [2020-06-25 12:33] – [4.5 Rx port function] tabreu
Line 376: Line 376:
 Available options: Available options:
  
-  - **Remote on/off (This is the default setting on all larger models)**. This setting allows remote on/off control: (0V = switch charger off, +5V (or a signal sent via VE.Direct communication) = switch charger on). An example of this operation is when the unit is connected to a [[https://www.victronenergy.com/accessories/ve-bus-bms|VE.BUS BMS]] (using a [[https://www.victronenergy.com/accessories/ve-direct-non-inverting-remote-on-off-cable|VE.Direct non inverting remote on-off cable, ASS030550300]]).+  - **Remote on/off (This is the default setting on all larger models)**. This setting allows remote on/off control: (Pin to GND = switch charger off, Pin floating or to battery+ (or a signal sent via VE.Direct communication) = switch charger on). An example of this operation is when the unit is connected to a [[https://www.victronenergy.com/accessories/ve-bus-bms|VE.BUS BMS]] (using a [[https://www.victronenergy.com/accessories/ve-direct-non-inverting-remote-on-off-cable|VE.Direct non inverting remote on-off cable, ASS030550300]]).
   - **Load output configuration (This is the default setting on the following models: 75/10, 75/15, 100/15 and 100/20)**. The Tx pin can be used to place a jumper to select load output operation. See Load output chapter (**4.2** above) for details. This only applies to the 10A, 15A and 20A chargers with a load output.   - **Load output configuration (This is the default setting on the following models: 75/10, 75/15, 100/15 and 100/20)**. The Tx pin can be used to place a jumper to select load output operation. See Load output chapter (**4.2** above) for details. This only applies to the 10A, 15A and 20A chargers with a load output.
   - **Load output on/off inverted** This setting reverses the load output on/off control: (0V = switch load output on, +5V = switch load output off)   - **Load output on/off inverted** This setting reverses the load output on/off control: (0V = switch load output on, +5V = switch load output off)