victronconnect:mppt-solarchargers [2020-05-25 19:31] – [4.2 Load output] mvadervictronconnect:mppt-solarchargers [2020-06-23 09:18] – [4.1 Battery settings] tabreu
Line 131: Line 131:
  
 //Fixed absorption time:// //Fixed absorption time://
-The same length of absorption is applied every day (when there is enough solar power) by using the maximum absorption time setting. Be aware that this option can result in overcharging your batteries, especially for lead batteries and system with shallow daily discharges. See your battery manufacturer for recommended settings.+The same length of absorption is applied every day (when there is enough solar power) by using the maximum absorption time setting. Be aware that this option can result in overcharging your batteries, especially for lead batteries and system with shallow daily discharges. See your battery manufacturer for recommended settings.  
 +//Note:// make sure to disable the tail current setting to make the same absorption time every day. The tail current could end absorption time sooner if the battery current is below the threshold. See more information on the tail current setting section below.
  
 //Adaptive absorption time:// //Adaptive absorption time://