 === Start Equalization now === === Start Equalization now ===
-Selecting 'Start Equalization now' allows manual initiation of an Equalization cycle. To allow the charger to equalize the battery properly use the manual equalize option only during absorption and float periods, and when there is sufficient sunlight. Current and voltage limits are identical to the automatic equalize function. The duration of the equalisation cycle is limited to a maximum of 1 hour when triggered manually. Manual equalization can be stopped at any time by selecting 'Stop Equalize'. Note that manual equalization is not available on all models.+Selecting 'Start Equalization now' allows manual initiation of an Equalization cycle. To allow the charger to equalize the battery properly use the manual equalize option only during absorption and float periods, and when there is sufficient sunlight. Current and voltage limits are identical to the automatic equalize function. The duration of the equalisation cycle is limited to a maximum of 1 hour when triggered manually. Manual equalization can be stopped at any time by selecting 'Stop Equalize'.
  
 === Temperature compensation === === Temperature compensation ===
Line 301: Line 301:
 {{:victronconnect:vc4_iphone_bluesolar_rxportsettings.png?direct&150|VictronConnect - MPPT RX port settings}} {{:victronconnect:vc4_iphone_bluesolar_rxportsettings.png?direct&150|VictronConnect - MPPT RX port settings}}
  
-The Rx pin on the VE.Direct connector can be used for other functions. This functionality was introduced in firmware version 1.17 and applies to the 10A, 15A and 20A chargers with a load output.+The Rx pin on the VE.Direct connector can be used for other functions. This functionality was introduced in firmware version 1.17.
 Available options: Available options:
  
   - **Remote on/off (This is the default setting on all larger models)**. This setting allows remote on/off control: (0V = switch charger off, +5V (or a signal sent via VE.Direct communication) = switch charger on). An example of this operation is when the unit is connected to a [[https://www.victronenergy.com/accessories/ve-bus-bms|VE.BUS BMS]] (using a [[https://www.victronenergy.com/accessories/ve-direct-non-inverting-remote-on-off-cable|VE.Direct non inverting remote on-off cable, ASS030550300]]).   - **Remote on/off (This is the default setting on all larger models)**. This setting allows remote on/off control: (0V = switch charger off, +5V (or a signal sent via VE.Direct communication) = switch charger on). An example of this operation is when the unit is connected to a [[https://www.victronenergy.com/accessories/ve-bus-bms|VE.BUS BMS]] (using a [[https://www.victronenergy.com/accessories/ve-direct-non-inverting-remote-on-off-cable|VE.Direct non inverting remote on-off cable, ASS030550300]]).
-  - **Load output configuration (This is the default setting on the following models: 75/10, 75/15, 100/15 and 100/20)**. The Tx pin can be used to place a jumper to select load output operation. See Load output chapter (**4.2** above) for details.+  - **Load output configuration (This is the default setting on the following models: 75/10, 75/15, 100/15 and 100/20)**. The Tx pin can be used to place a jumper to select load output operation. See Load output chapter (**4.2** above) for details. This only applies to the 10A, 15A and 20A chargers with a load output.
   - **Load output on/off inverted** This setting reverses the load output on/off control: (0V = switch load output on, +5V = switch load output off)   - **Load output on/off inverted** This setting reverses the load output on/off control: (0V = switch load output on, +5V = switch load output off)
   - **Load output on/off normal** This setting allows load output on/off control: (0V = switch load output off, +5V = switch load output on)   - **Load output on/off normal** This setting allows load output on/off control: (0V = switch load output off, +5V = switch load output on)