victronconnect:mppt-solarchargers [2019-04-24 14:44] – [5. Programmable relay] jcecilvictronconnect:mppt-solarchargers [2019-06-25 16:06] mvader
Line 118: Line 118:
 Enter the time value in the notation hh:mm, where hours are between 0 and 12; and minutes are between 0 and 59. Enter the time value in the notation hh:mm, where hours are between 0 and 12; and minutes are between 0 and 59.
  
-The maximum duration of the absorption period is determined by the battery voltage as measured just before the solar charger begins operation each morning (12V battery assumed):+The charge algorithm uses an adaptive absorption time: it automatically adapts to the state of charge in the morning. The maximum duration of the absorption period is determined by the battery voltage as measured just before the solar charger begins operation each morning (12V battery assumed):
  
 ^Battery voltage Vb (@start-up) ^ Multiplier ^ Maximum absorption times ^ ^Battery voltage Vb (@start-up) ^ Multiplier ^ Maximum absorption times ^
Line 163: Line 163:
  
 === Start Equalization now === === Start Equalization now ===
-Selecting 'Start Equalization now' allows manual initiation of an Equalization cycle. To allow the charger to equalize the battery properly use the manual equalize option only during absorption and float periods, and when there is sufficient sunlight. Current and voltage limits are identical to the automatic equalize function. The duration of the equalisation cycle is limited to a maximum of 1 hour when triggered manually. Manual equalization can be stopped at any time by selecting 'Stop Equalize'. Note that manual equalization is not available on all models.+Selecting 'Start Equalization now' allows manual initiation of an Equalization cycle. To allow the charger to equalize the battery properly use the manual equalize option only during absorption and float periods, and when there is sufficient sunlight. Current and voltage limits are identical to the automatic equalize function. The duration of the equalisation cycle is limited to a maximum of 1 hour when triggered manually. Manual equalization can be stopped at any time by selecting 'Stop Equalize'.
  
 === Temperature compensation === === Temperature compensation ===