User Tools

Site Tools


victronconnect:mppt-solarchargers

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
Next revisionBoth sides next revision
victronconnect:mppt-solarchargers [2019-01-22 10:16] – external edit 127.0.0.1victronconnect:mppt-solarchargers [2019-06-24 10:04] mvader
Line 10: Line 10:
  
 ===== 2. STATUS - Live Data Information ===== ===== 2. STATUS - Live Data Information =====
-{{:victronconnect:vc4_iphone_bluesolar_live.png?direct&150|VictronConnect - MPPT}}+{{:victronconnect:vc5_iphone_bluesolar_live.png?direct&175|VictronConnect - MPPT}}
  
   * **MPPT [Model Number]**  confirms the connected device. A custom name can also be set if desired.   * **MPPT [Model Number]**  confirms the connected device. A custom name can also be set if desired.
Line 19: Line 19:
     * Bulk: During this stage the Controller delivers as much charge current as possible to rapidly charge the batteries. When the battery voltage reaches the Absorption voltage setting, the Controller activates the Absorption stage.     * Bulk: During this stage the Controller delivers as much charge current as possible to rapidly charge the batteries. When the battery voltage reaches the Absorption voltage setting, the Controller activates the Absorption stage.
     * Absorption: During this stage the Controller switches to the constant voltage mode, where a pre-set absorption voltage, suitable to the battery type (See section 4.1 Battery Settings below), is applied. When the charge current decreases below the Tail current and/or the pre-set Absorption time has elapsed, the battery is fully charged. The Controller switches to the Float stage. The Tail current is 1A for models 100/20 and smaller; and 2A for larger models. (When an automatic equalisation is being performed this will also be reported as 'Absorption'.)     * Absorption: During this stage the Controller switches to the constant voltage mode, where a pre-set absorption voltage, suitable to the battery type (See section 4.1 Battery Settings below), is applied. When the charge current decreases below the Tail current and/or the pre-set Absorption time has elapsed, the battery is fully charged. The Controller switches to the Float stage. The Tail current is 1A for models 100/20 and smaller; and 2A for larger models. (When an automatic equalisation is being performed this will also be reported as 'Absorption'.)
-    * Float: During this stage the float voltage is applied to the battery to maintain a fully-charged state.+    * Float: During this stage the float voltage is applied to the battery to maintain a fully-charged state. When the battery voltage drops below float voltage during at least 1 minute, a new charge cycle will be triggered.
     * Equalization: This is shown when 'Start equalization now' is pressed in the battery settings. The charger applies the equalization voltage to the battery as long as the current level stays below 8% (Gel or AGM) or 25% (tubular plate) of the bulk current.      * Equalization: This is shown when 'Start equalization now' is pressed in the battery settings. The charger applies the equalization voltage to the battery as long as the current level stays below 8% (Gel or AGM) or 25% (tubular plate) of the bulk current. 
  
Line 37: Line 37:
 You can only tell if that is the case with Charge Controllers which have all loads connected to the load output terminals. Remember: any loads connected directly to the battery can't be monitored by the Solar Charger. You can only tell if that is the case with Charge Controllers which have all loads connected to the load output terminals. Remember: any loads connected directly to the battery can't be monitored by the Solar Charger.
 ===== 3. HISTORY - Thirty-day Graphic ===== ===== 3. HISTORY - Thirty-day Graphic =====
-{{:victronconnect:vc4_iphone_bluesolar_history.png?direct&150|VictronConnect - MPPT history}}+{{:victronconnect:vc5_iphone_bluesolar_history.png?direct&175|VictronConnect - MPPT history}}
  
 (The fragmented square icon (top left) allows you to toggle between 'portrait' and 'landscape' screen presentations.) (The fragmented square icon (top left) allows you to toggle between 'portrait' and 'landscape' screen presentations.)
Line 71: Line 71:
    
 ===== 4. Settings ===== ===== 4. Settings =====
-{{:victronconnect:vc4_iphone_bluesolar_settings.png?direct&150|VictronConnect - MPPT settings}}+{{:victronconnect:vc5_iphone_bluesolar_settings.png?direct&175|VictronConnect - MPPT settings}}
  
 The settings page is accessed by clicking on the Cog icon at the top right of the Home page. The settings page provides access to view or change the settings of the Battery; Load; Streetlight; and Port functions. From this page you can also view Product information such as the Firmware versions installed on the MPPT Solar Charger.  The settings page is accessed by clicking on the Cog icon at the top right of the Home page. The settings page provides access to view or change the settings of the Battery; Load; Streetlight; and Port functions. From this page you can also view Product information such as the Firmware versions installed on the MPPT Solar Charger. 
  
 ==== 4.1 Battery settings ==== ==== 4.1 Battery settings ====
-{{:victronconnect:vc4_iphone_bluesolar_batterysettings.png?direct&150|VictronConnect - MPPT battery settings}}+{{:victronconnect:vc5_iphone_bluesolar_batterysettings.png?direct&175|VictronConnect - MPPT battery settings}}
  
 For small MPPT Solar Charger models there is only one preset. Larger models feature a rotary switch, the battery page shows the setting of the rotary switch. For small MPPT Solar Charger models there is only one preset. Larger models feature a rotary switch, the battery page shows the setting of the rotary switch.
Line 118: Line 118:
 Enter the time value in the notation hh:mm, where hours are between 0 and 12; and minutes are between 0 and 59. Enter the time value in the notation hh:mm, where hours are between 0 and 12; and minutes are between 0 and 59.
  
-The maximum duration of the absorption period is determined by the battery voltage as measured just before the solar charger begins operation each morning (12V battery assumed):+The charge algorithm uses an adaptive absorption time: it automatically adapts to the state of charge in the morning. The maximum duration of the absorption period is determined by the battery voltage as measured just before the solar charger begins operation each morning (12V battery assumed):
  
 ^Battery voltage Vb (@start-up) ^ Multiplier ^ Maximum absorption times ^ ^Battery voltage Vb (@start-up) ^ Multiplier ^ Maximum absorption times ^
Line 177: Line 177:
  
 === Low temperature cut-off === === Low temperature cut-off ===
-This setting is available when a VE.Smart network is set-up and the battery temperature is available (e.g. by using a Smart Battery Sense or a Smart BMV with temperature sensor). It can be used to disable charging at low temperatures as required by Lithium batteries. +This setting is available when a VE.Smart network is set-up and the battery temperature is available (e.g. by for example using a Smart Battery Sense or a Smart BMV with the optional temperature sensor). It can be used to disable charging at low temperatures as required by Lithium batteries. 
  
 For Lithium Iron Phosphate batteries this setting is preset at 5 degrees Celsius, for the other battery types it is disabled. When creating a user defined battery the cut-off temperature level can be adjusted manually. For Lithium Iron Phosphate batteries this setting is preset at 5 degrees Celsius, for the other battery types it is disabled. When creating a user defined battery the cut-off temperature level can be adjusted manually.
  
 +See the [[victronconnect:ve-smart-networking|VE.Smart Network manual]] for details on what devices are capable of transmitting temperature.
 ==== 4.2 Load output  ==== ==== 4.2 Load output  ====
 This section applies to all products. These settings are typically used on the smaller models which have a dedicated load output (75/10, 75/15, 100/15 and 100/20). This section applies to all products. These settings are typically used on the smaller models which have a dedicated load output (75/10, 75/15, 100/15 and 100/20).
Line 186: Line 187:
 For larger models without a load output, the load settings can be used to drive the TX pin in the VE.Direct port, which can then be used to drive a [[https://www.victronenergy.com/battery_protect/battery-protect|BatteryProtect]] relay or other load-shedding device. See [[#Tx port function|chapter 4.4 Tx port function]], option 5: Virtual Load output, for more information. For larger models without a load output, the load settings can be used to drive the TX pin in the VE.Direct port, which can then be used to drive a [[https://www.victronenergy.com/battery_protect/battery-protect|BatteryProtect]] relay or other load-shedding device. See [[#Tx port function|chapter 4.4 Tx port function]], option 5: Virtual Load output, for more information.
  
-{{:victronconnect:vc4_iphone_bluesolar_loadouputsettings.png?direct&150|VictronConnect - MPPT load output settings}}+{{:victronconnect:vc5_iphone_bluesolar_loadoutputsettings.png?direct&175|VictronConnect - MPPT load output settings}}
  
 The available programs are: The available programs are:
Line 212: Line 213:
 ==== 4.3 Streetlight settings ====  ==== 4.3 Streetlight settings ==== 
  
-{{:victronconnect:vc4_iphone_bluesolar_streetlightsettings.png?direct&150|VictronConnect - MPPT Streetlight}}+{{:victronconnect:vc5_iphone_bluesolar_streetlight.png?direct&175|VictronConnect - MPPT Streetlight}}
  
 The Streetlight function allows you to automatically control night lighting - it's duration, and brilliance. When the Streetlight function is enabled a timer program can be created whereby 'sunset' and 'sunrise' are used as the anchor points for the timer program. The advantage of this is that the programme will adjust itself to the duration of night-time as it changes with the season. Note that the internal clock will need a few days of uninterrupted operation to synchronize with sunrise and sunset and whilst this is happening a 12-hour day, and a 12-hour night will be assumed. The Streetlight function allows you to automatically control night lighting - it's duration, and brilliance. When the Streetlight function is enabled a timer program can be created whereby 'sunset' and 'sunrise' are used as the anchor points for the timer program. The advantage of this is that the programme will adjust itself to the duration of night-time as it changes with the season. Note that the internal clock will need a few days of uninterrupted operation to synchronize with sunrise and sunset and whilst this is happening a 12-hour day, and a 12-hour night will be assumed.
Line 284: Line 285:
 This setting defines the function of the Tx pin located inside the VE.Direct connector. Use the [[https://www.victronenergy.com/cables/ve-direct-tx-digital-output-cable|VE.Direct TX digital output cable, ASS030550500]] to access - and therefore receive signals from - the pin. This setting defines the function of the Tx pin located inside the VE.Direct connector. Use the [[https://www.victronenergy.com/cables/ve-direct-tx-digital-output-cable|VE.Direct TX digital output cable, ASS030550500]] to access - and therefore receive signals from - the pin.
  
-{{:victronconnect:vc4_iphone_bluesolar_txportsettings.png?direct&150|VictronConnect - MPPT TX port settings settings}}+{{:victronconnect:vc5_iphone_bluesolar_txport.png?direct&175|VictronConnect - MPPT TX port settings settings}}
  
 Available options: Available options:
Line 311: Line 312:
  
 ==== 5. Programmable relay ==== ==== 5. Programmable relay ====
-{{:victronconnect:vc4_iphone_mppt_relaysettings.png?150|VictronConnect - Relay}}+{{:victronconnect:vc5_iphone_bluesolar_relay.png?175|VictronConnect - Relay}}
  
 A programmable relay switch is available on some SmartSolar models. The datasheet for your model will tell you whether or not it is available. A programmable relay switch is available on some SmartSolar models. The datasheet for your model will tell you whether or not it is available.
victronconnect/mppt-solarchargers.txt · Last modified: 2021-09-30 07:16 by guystewart

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki