venus-os:start
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
venus-os:start [2019-08-23 08:38] – guy_stewart | venus-os:start [2019-11-13 11:25] – [Comparison table] mbosma | ||
---|---|---|---|
Line 35: | Line 35: | ||
^ __Victron comm. ports__ | ^ __Victron comm. ports__ | ||
| VE.Direct ports (always isolated) | | VE.Direct ports (always isolated) | ||
- | | VE.Can | ||
| VE.Bus | | VE.Bus | ||
+ | | VE.Can | ||
^ __Non Victron-products__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II GX and EasySolar-II GX ^ | ^ __Non Victron-products__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II GX and EasySolar-II GX ^ | ||
| Canbus-BMS batteries | | Canbus-BMS batteries | ||
Line 43: | Line 43: | ||
| ABB PV Inverters | | ABB PV Inverters | ||
| SolarEdge PV Inverters | | SolarEdge PV Inverters | ||
+ | | [[https:// | ||
^ __Communication__ | ^ __Communication__ | ||
| USB | 2 USB Host ports – not isolated | | USB | 2 USB Host ports – not isolated | ||
Line 50: | Line 51: | ||
| Micro SDcard slot | SDHC cards up to max. of 32GB. < | | Micro SDcard slot | SDHC cards up to max. of 32GB. < | ||
| Second CAN-bus port | no | yes - non-isolated | | Second CAN-bus port | no | yes - non-isolated | ||
+ | | BMS-Can port < | ||
| Built-in RS485 | | Built-in RS485 | ||
^ __IO__ | ^ __IO__ | ||
Line 88: | Line 90: | ||
- Requires the [[https:// | - Requires the [[https:// | ||
- The 5V output on the Venus GX can be used to power, for example, a USB hub. Note that its output is not current limited or otherwise protected, and it shares the internal power supply in the Venus GX: overdrawing from it will result in shutdown(s) of the Venus GX. It is recommended to install a fuse for prevention. | - The 5V output on the Venus GX can be used to power, for example, a USB hub. Note that its output is not current limited or otherwise protected, and it shares the internal power supply in the Venus GX: overdrawing from it will result in shutdown(s) of the Venus GX. It is recommended to install a fuse for prevention. | ||
+ | - Though the Maxi GX, MultiPlus-II GX and EasySolar-II GX all have a dual set of RJ-45 sockets labelled VE.Can, this port is actually a dedicated BMS-Can port. It can only be used to connected to managed batteries like Freedomwon, BYD, Pylontech and others, at 500kbps. The hardware does not meet the requirements for a VE.Can port; and thus it is not possible to use to port to connect Victron products such as the SmartSolar VE.Can MPPT product range. Note that current version of Venus OS firmware still allows to select the VE.Can function and other baudrates. The result will be unreliable, and future firmware versions will lock the feature to BMS-Can only and 500kbps. | ||
+ | - A BMS-Can port is a port dedicated to be used for connecting managed batteries, like BYD, Pylontech, Freedomwon and others, only. It is not possible to connect Victron VE.Can products to that port. To connect such managed battery, use our [special cables](https:// |