Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision |
venus-os:start [2019-05-16 21:28] – [Comparison table] krenzke | venus-os:start [2019-05-28 08:56] – [Comparison table] mvader |
---|
===== Introduction ===== | ===== Introduction ===== |
| |
GX products are Victron's state-of-the-art monitoring solution. The family consists of the different Venus-device models, and their accessories. | GX products are Victron's state-of-the-art monitoring solution. The family consists of the different GX products, and their accessories. |
| |
The Venus-device lies at the heart of the system - providing monitoring, and operating as the communication-centre of your installation. All the other system-components - such as inverter/chargers, solar chargers, and batteries - are connected to it. The Venus-device ensures that they all work in harmony. Monitoring can be carried out locally ...or remotely - via our free-to-use Victron Remote Management portal ([[https://vrm.victronenergy.com|VRM]]). The Venus device also provides [[vrm_portal:remote-firmware-update|Remote firmware updates]] and even allows the settings to be [[vrm_portal:remote-veconfigure|Changed Remotely]]. | The GX-device lies at the heart of the system - providing monitoring, and operating as the communication-centre of your installation. All the other system-components - such as inverter/chargers, solar chargers, and batteries - are connected to it. The Venus-device ensures that they all work in harmony. Monitoring can be carried out locally ...or remotely - via our free-to-use Victron Remote Management portal ([[https://vrm.victronenergy.com|VRM]]). The GX-device also provides [[vrm_portal:remote-firmware-update|Remote firmware updates]] and even allows the settings to be [[vrm_portal:remote-veconfigure|Changed Remotely]]. |
| |
The Venus devices are: | The GX Family consists of these models: |
* [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] | * [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|Color Control GX]] |
* [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|Venus GX]] | * [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|Venus GX]] |
* [[https://www.victronenergy.com/panel-systems-remote-monitoring/octo-gx|Octo GX]] - The Octo GX is particularly suited to installations which have many MPPT Solar Chargers, as it has 10 VE.Direct ports | |
* [[https://www.victronenergy.com/panel-systems-remote-monitoring/canvu-gx|The CANvu GX]] is best for harsh environments - when its IP67 rating is a must. | * [[https://www.victronenergy.com/panel-systems-remote-monitoring/canvu-gx|The CANvu GX]] is best for harsh environments - when its IP67 rating is a must. |
| * [[https://www.victronenergy.com/panel-systems-remote-monitoring/octo-gx|Octo GX]] - The Octo GX is particularly suited to medium size installations which have many MPPT Solar Chargers, as it has 10 VE.Direct ports |
| * Maxi GX - suited for systems having many MPPT Solar Chargers, as it has 25 VE.Direct ports. |
| |
| Also, there is a GX device built into our MultiPlus-II GX and EasySolar-II GX Inverter/chargers. There, its referred to as the GX Card. |
| |
| |
| |
===== Comparison table ===== | ===== Comparison table ===== |
^ __User interface__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ | ^ __User interface__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| Appearance | {{ :ccgx:ccgx_product.png?direct&100 |}} | {{ :ccgx:venusgx_product.png?direct&100 |}} | {{ :ccgx:octogx_product.png?direct&100 |}} | {{ :ccgx:canvu_product.png?direct&100 |}} | | | Appearance | {{ :ccgx:ccgx_product.png?direct&100 |}} | {{ :ccgx:venusgx_product.png?direct&100 |}} | {{ :ccgx:octogx_product.png?direct&100 |}} | {{ :ccgx:canvu_product.png?direct&100 |}} | |
| Display | LCD Display & 7 buttons | no display | no display | 4.3" touch-screen | 2x16 character display | | | Display | LCD Display & 7 buttons | no display | no display | 4.3" touch-screen | 2x16 character display || |
| Remote Console | yes ||||| | | Remote Console | yes |||||| |
| Buzzer | yes | yes | no | yes | no | | | Buzzer | yes | yes | no | yes | no || |
^ __Documentation__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ | ^ __Documentation__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| Manual | [[ccgx:start|CCGX manual]] | [[venus-gx:start|VGX manual]] | [[venus-os:octo-gx|OGX manual]] | [[venus-os:canvu-gx|CANvu manual]] | tbd | | | Manual | [[ccgx:start|CCGX manual]] | [[venus-gx:start|VGX manual]] | [[venus-os:octo-gx|OGX manual]] | [[venus-os:canvu-gx|CANvu manual]] | tbd | [[https://ve3.nl/multiplus-ii-gx|MultiPlus-II GX]] | |
| Product detail page | [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|CCGX product]] | [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|VGX product]] | [[https://www.victronenergy.com/panel-systems-remote-monitoring/octo-gx|OGX product]] | [[https://www.victronenergy.com/accessories/canvu-gx|CANvu product]] | tbd | | | Product detail page | [[https://www.victronenergy.com/panel-systems-remote-monitoring/color-control|CCGX product]] | [[https://www.victronenergy.com/panel-systems-remote-monitoring/venus-gx|VGX product]] | [[https://www.victronenergy.com/panel-systems-remote-monitoring/octo-gx|OGX product]] | [[https://www.victronenergy.com/accessories/canvu-gx|CANvu product]] | tbd | |
^ __Victron comm. ports__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX<sup>(12)</sup> ^ Maxi GX ^ | ^ __Victron comm. ports__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX<sup>(12)</sup> ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| VE.Direct ports | 2 <sup>(1)</sup> || 10 <sup>(1)</sup> | 3 <sup>(1)</sup> | 25 | | | VE.Direct ports (always isolated) | 2 <sup>(1)</sup> || 10 <sup>(1)</sup> | 3 <sup>(1)</sup> | 25 | 1 | |
| VE.Can | 2 paralleled RJ45 sockets – isolated ||||| | | VE.Can | 2 paralleled RJ45 sockets – isolated ||||| 2 paralleled RJ45 sockets - isolated | |
| VE.Bus | 2 paralleled RJ45 sockets – isolated |||| 1 isolated RJ45 socket | | | VE.Bus | 2 paralleled RJ45 sockets – isolated |||| 1 isolated RJ45 socket | 2 paralleled RJ45 sockets | |
^ __Non Victron-products__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ | ^ __Non Victron-products__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| Canbus-BMS batteries | Many battery brands. See [[battery_compatibility:start|here ]] for details ||||| | | Canbus-BMS batteries | Many battery brands. See [[battery_compatibility:start|here ]] for details |||||| |
| Fronius PV Inverters | See [[ccgx:ccgx_fronius|here]] for details ||||| | | Fronius PV Inverters | See [[ccgx:ccgx_fronius|here]] for details |||||| |
| SMA PV Inverters | See [[ccgx:ccgx_sma|here]] for details ||||| | | SMA PV Inverters | See [[ccgx:ccgx_sma|here]] for details |||||| |
^ __Communication__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ | | ABB PV Inverters | See [[ccgx:abb|here]] for details |||||| |
| USB | 2 USB Host ports – not isolated || 1 USB Host port - not isolated ||| | | SolarEdge PV Inverters | See [[venus-os:gx_solaredge|here]] for details |||||| |
| Ethernet | 10/100 RJ45 socket - isolated except shield ||| 1 port. isolation?<sup>(12)</sup> | 10/100 RJ45 socket | | ^ __Communication__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| WiFi | optional <sup>(2)</sup> | built-in, but see <sup>(3)</sup> | built-in, external antenna <sup>(11)</sup> | optional <sup>(2)</sup> | no | | | USB | 2 USB Host ports – not isolated || 1 USB Host port - not isolated |||| |
| Bluetooth Smart | no ||||| | | Ethernet | 10/100 RJ45 socket - isolated except shield ||| 1 port. isolation?<sup>(12)</sup> | 10/100 RJ45 socket || |
| Micro SDcard slot | SDHC cards up to max. of 32GB. <sup>(5)</sup> ||| no | yes | | | WiFi | optional <sup>(2)</sup> | built-in, but see <sup>(3)</sup> | built-in, external antenna <sup>(11)</sup> | optional <sup>(2)</sup> | no | built-in | |
| Second CAN-bus port | no | yes - non-isolated | yes - non-isolated | yes - non-isolated | no | | | Bluetooth Smart | no |||||| |
| RS485 | no | no | yes - non-isolated | no || | | Micro SDcard slot | SDHC cards up to max. of 32GB. <sup>(5)</sup> ||| no | yes | no | |
^ __IO__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX<sup>(12)</sup> ^ Maxi GX ^ | | Second CAN-bus port | no | yes - non-isolated | yes - non-isolated | yes - non-isolated | no | no | |
| Programmable relay <sup>(7)</sup> | 1x NO | 1x NO / NC <sup>(8)</sup> | 1x NO / NC || 1x NO / NC <sup>(8)</sup> | | | Built-in RS485 | no | no | yes - non-isolated | no || no | |
| Resistive tank level inputs | no | 3 <sup>(9)</sup> | no ||| | ^ __IO__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX<sup>(12)</sup> ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| Temperature measurements | no | 2 <sup>(10)</sup> | no || | | Programmable relay <sup>(7)</sup> | 1x NO | 1x NO / NC <sup>(8)</sup> | 1x NO / NC || 1x NO / NC <sup>(8)</sup> | n/a | |
| Digital Inputs | no | 5 | 3 | 1 | 4 | | | Resistive tank level inputs | no | 3 <sup>(9)</sup> | no |||| |
^ __Other__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ | | Temperature sense inputs | no | 2 <sup>(10)</sup> | no |||| |
| Supply voltage | 8 - 70 VDC ||| 8 - 32 VDC | 32 - 70 VDC | | | Digital Inputs | no | 5 | 3 | 1 | 4 | no | |
| Mounting | Panel Integration | Wall mounting | DIN Rail (35mm) | Panel | Wall mount IP65 | | ^ __Other__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| | Supply voltage | 8 - 70 VDC ||| 8 - 32 VDC | 32 - 70 VDC | ?? | |
| | Mounting | Panel Integration | Wall mounting | DIN Rail (35mm) | Panel | Wall mount IP65 | Built-in | |
| Outer dimensions ( h x w x d ) | 130 x 120 x 28 mm | 45 x 143 x 96 mm | 61 x 108 x 90 mm | ? | 600 x 380 x 210 mm | | | Outer dimensions ( h x w x d ) | 130 x 120 x 28 mm | 45 x 143 x 96 mm | 61 x 108 x 90 mm | ? | 600 x 380 x 210 mm | |
| Operating temperature | -20 to +50°C ||| -20 to +70°C | -20 to +50°C | | | Operating temperature | -20 to +50°C ||| -20 to +70°C | -20 to +50°C | |
| Battery backupped clock | yes ||| no | yes | | | Battery backuped clock | yes ||| no | yes | yes | |
^ __Standards__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ | ^ __Standards__ ^ CCGX ^ Venus GX ^ Octo GX ^ CANvu GX ^ Maxi GX ^ MultiPlus-II and EasySolar-II GX ^ |
| Safety | EN 60950 || ? | ? | ? | | | Safety | EN 60950 || ? | ? | ? | |
| EMC | EN 61000-6-3, EN 55014-1, EN 61000-6-2, EN 61000-6-1, EN 55014-2 ||||| | | EMC | EN 61000-6-3, EN 55014-1, EN 61000-6-2, EN 61000-6-1, EN 55014-2 ||||| |