Line 1: Line 1:
 ======= Remote VE.Bus firmware updates ======= ======= Remote VE.Bus firmware updates =======
  
-This document is a draft version of the new Remote Ve.Bus firmware update feature. Once officially released, this must be included into the main [[|https://www.victronenergy.com/live/vrm_portal:remote-firmware-update|VRM Remote Firmware update manual]].+===== 1Introduction and limitations ===== 
  
-===== 1. Firmware and hardware requirements =====+==== 1.1 Introduction ==== 
  
-  * Minimum installed firmware version must be 426 +This feature allows remotely updating the firmware of Victron inverter as well as inverter/charger. Applicable to systems that have a [[https://www.victronenergy.com/live/venus-os:start|GX device]] installedand being internet-connected to the [[https://vrm.victronenergy.com|VRM Portal]].
-  * GX Device minimum hardware +
-    * In case of a CCGX, it must have serial number HQ1707 or newer. +
-    * In case of another GX Deviceno special requirements.+
  
-In case either the minimum installed firmware is from before 426, or there is CCGX installed which has too old hardwarean error message is shown on VRM and it will refuse to start the firmware update.+The inverter/charger is the heart of a Victron power system. Also, certain types of installations require extra preparations. Therefore, before continuing, make sure to fully understand the process. 
 + 
 +This procedure includes migration of the settings. 
 + 
 +There is no limitation on the type of system: single unit systems, parallel, split-phase, three-phase and also large systems of 6, 9 and more inverters can all be updated remotely using this feature. 
 + 
 +It is not required to keep your Victron equipment updated to the latest firmware version. Stable systems should be left with their current firmware. Firmware updates should only be done when it is recommended to fix an issue you are experiencing, or add new feature that is required by the installation. 
 + 
 +==== 1.2 Limitations and requirements ==== 
 + 
 +  * Minimum already installed VE.Bus firmware version must be 426 
 +  * There must be no VE.Bus BMS connected to the VE.Bus network, and also no Digital Multi Control (DMC) panel. See section 2.2 for more information. 
 +  * In case of a Color Control GX (CCGX), it must have serial number HQ1707 or newer: see FAQ Q2 for how to check this. 
 +  * In case of another GX Device, ie. a Cerbo, Venus GX, or otherwise, there is no minimum hardware version - they all meet the requirements.  
 +  * Venus OS firmware must be 2.65 or later.  
 +  * Two Way Communication must be enabled in the VRM menu of the GX device
  
 ===== 2. Preparations ===== ===== 2. Preparations =====
Line 18: Line 30:
 An AC-Coupled PV-Inverter is a PV Inverter connected to the AC out of the Victron Inverter. An AC-Coupled PV-Inverter is a PV Inverter connected to the AC out of the Victron Inverter.
  
-To make sure no overcharging occurs, disable AC-Coupled PV Inverters. For example by having someone local to the system disconnect its solar input, or if it has an on/off switch: switch it off. Alternatively, perform the firmware update when the sun is down, in the evening or night. Or when the battery is far from fully charged.+To make sure no overcharging occurs, disable AC-Coupled PV Inverters. For example by having someone local to the system disconnect its solar input, or if it has an on/off switch: switch it off. Alternatively, perform the firmware update when the sun is down, in the evening or night.
  
-Why? After the firmware update, the system will be running in default configuration until the new settings are uploaded. The means that there is no PV Inverter Assistant installed; and PV Inverter controlling by AC Frequency shift is disabled.+The reason for having to do this is that the system will start-up while configured in factory defaults, and then doesn’t regulate PV Inverter output to manage the charging.
  
  
-==== 2.2 Systems with a VE.Bus BMS ====+==== 2.2 Disconnect VE.Bus BMS and/or Digital Multi Control ====
  
-During the firmware update, the VE.Bus BMS must be physically disconnected from the system: RJ-45 cable must be unplugged.+It is not possible to update a VE.Bus inverteror inverter/charger in case there is also a VE.Bus BMS or Digital Multi Control (DMC) connected to the VE.Bus network.  
 +This exception does not apply to a MultiPlus or Quattro with VE.Bus BMS V2. In such systems, a remote firmware update of the VE.Bus inverter or inverter/charger is possible.
  
-Izak is there more to know?+Error 734, “Cannot update with DMC or VE.Bus BMS connected” will be shown during the process when attempting to update such system. No settings or firmware is altered at the time, the system will remain operational. 
 + 
 +To update such system remotely, first get someone local to temporarily unplug the RJ-45 connection on the VE.Bus BMS and/or the DMC. Note that the inverter will switch off when doing that. And that it then might be necessary to provide an alternate power supply for the GX device as it will lose power.
  
 ==== 2.3 Systems where the internet connection will be lost while inverters are off ==== ==== 2.3 Systems where the internet connection will be lost while inverters are off ====
Line 39: Line 54:
  
 NOTE: we're currently still improving this use case. Once completed, the VRM Portal will keep trying to connect for a reasonable time compared to the number of devices that need updating. Which it will do in a manner where its clear for the user that there is no reason (yet) to worry. All this will be completed before official release. The FAQ entry will stay in case something does go wrong. NOTE: we're currently still improving this use case. Once completed, the VRM Portal will keep trying to connect for a reasonable time compared to the number of devices that need updating. Which it will do in a manner where its clear for the user that there is no reason (yet) to worry. All this will be completed before official release. The FAQ entry will stay in case something does go wrong.
 +
 ==== 2.4 Be 100% sure that the GX Device is not powered by the inverter ==== ==== 2.4 Be 100% sure that the GX Device is not powered by the inverter ====
  
Line 46: Line 62:
  
 Careful: this is not automatically verified in any way. Careful: this is not automatically verified in any way.
 +
 +Testing this on site is easy: switch the inverter off. In case the GX Device remains powered: OK. If not, not OK.
  
 ==== 2.5 Have the latest VEConfigure Tools ==== ==== 2.5 Have the latest VEConfigure Tools ====
  
-For now, they are only available through this [[https://www.dropbox.com/s/7uhk7svkfbt84ax/VEConfig%20tools%20Beta.zip?dl=1|beta link]]to be installed manually.+The latest version available on our website includes the necessary featuresIf you start VEConfigure or VE.Bus System Configurator while connected to the internetit will automatically check and update itself when necessary.
  
-Once officially released, this text will be replaced by minimum firmware version numbers.+Not having the latest version of VEConfigure Tools installed will result in an error when opening the file.
  
-Not having the latest file installed will result in an error when opening the file (@Jos please confirm by testing) +===== 3. Step by Step Procedure Video =====
-===== 3. Procedure =====+
  
 The inverter/charger is the heart of a Victron power system. Before continuing, make sure to fully understand the process.  The inverter/charger is the heart of a Victron power system. Before continuing, make sure to fully understand the process. 
  
-__First stage__ +This video demonstrates the process: 
-The first stage consists of 5 steps:+ 
 +{{vimeo>519951729?medium}} 
 + 
 +==== 3.1 Checking installed version ==== 
 + 
 +In the VRM Portal, go to the Device List page, and click the Firmware update button at the bottom of the page. The system will now search for connected devices and once completed show the result: 
 + 
 +{{ :venus-os:fw_update_device_list2.png?nolink |}} 
 + 
 +==== 3.2 First stage - retrieving current configuration & doing the update ==== 
 + 
 +Once the command is given to update the firmware, this is what happens:
  
   - The new firmware file is uploaded to the GX Device.   - The new firmware file is uploaded to the GX Device.
   - The configuration is retrieved from the VE.Bus system.   - The configuration is retrieved from the VE.Bus system.
-  - The inverter is switched off and its firmware is updated. Be aware that there will be no AC power available. Also the internet connection might be lost, in case the router is powered by the inverter. Which is OKthis update has been designed to remotely update an Off-grid system+  - The inverter is switched off and its firmware is updated. In case the internet router is powered by the inverter, the connection to the installation will now be lost until the update is completedThis is OKthis mechanism has been designed to handle such installation
-  - After the firmware update is completed, the settings will be reset to defaults and, to prevent overcharging, the charge current will be set to zero amps to prevent overcharging from mains, and then the inverter is switched on again+  - After the firmware update is completed, the inverter is switched on again. The settings will have been reset to their defaults. And, to prevent overcharging, all charge voltages have been set to the nominal battery voltage, being 12V, 24V or 48V. This effectively disables the charger. Note that this works a bit different for systems with a managed battery, usually connected via a CAN-Bus. For such systems, the system will be charging, within limits as provided by the BMS. 
-  - The internet connection will be re-established (in case it was lost) and the new settings template is retrieved from the system; after which it will be uploaded to your web browser.+ 
 +Now, the inverter is powered up, configured with default settings. In case the internet was lost, it will recover which might take a while to fully reconnect all systems. Once restored, the new settings template is retrieved from the system and will be available for download in your web browser. 
 + 
 +At this pointthe web browser shows below message. Note the downloaded settings template on the lower right: 
 + 
 +{{ :venus-os:vrm_remote_update_success_message.png?nolink&600 |}} 
 + 
 +==== 3.3 Second stage - converting and restoring configuration ==== 
 + 
 +Make sure you have the latest version of the [[https://www.victronenergy.com.au/Executables/VEConfig/VECSetup_B.exe|VE.Bus configuration tools]] installed. 
 + 
 +The settings template will need to be converted. It should be a .RVMS file in your download folder (it is saved during the update procedure). Open it by double clicking. If the VE.Bus tools are correctly installed, it will then open in VE.Bus System Configurator, and prompt you about the conversion.  
 + 
 +Close VEConfigure (X on upper right of the window), which will automatically prompt saving that converted file: 
 + 
 +{{ :venus-os:veconfigure_save_remote_file.png?nolink&600 |}} 
 + 
 +Now upload the converted file. On the VRM Portal, go to the Device List -> Remote VEConfigure menu -> 'Upload' the converted file. 
 + 
 +This step will restore the charge voltage and all other configuration settings as they were programmed prior to the firmware update. 
 + 
 +===== 5. Error codes & trouble shooting ===== 
 +=== Error 733 === 
 +This error is generated by the updater logic on the GX deviceIt show the reason why a firmware update failed. The Error 733 message box will contain an error message with or without a code.   
 + 
 +The most common reasons are: 
 +^ Message ^ Description ^  
 +| vbdup failed with exit code 54  | Failed to start Update. The file has an incompatible version number. \\ Please update your Venus OS version to the latest version |  
 +| vbdup failed with exit code 123 | One or more firmware file(s) supplied do not match the connected device models. | 
 +  
 +   
 + 
 + 
 +=== Error 1342 Not updatable === 
 + 
 +This errors shows in case either the minimum installed firmware is from before 426, or there is a CCGX installed which has too old hardware. 
 + 
 +The already installed firmware version can be see here, the encircled number must be above 426. 
 + 
 + 
 +How to check if the CCGX is new enough, see FAQ Q2. 
 + 
 +=== VEConfigure tools File corrupt error === 
 + 
 +Most likely you are opening the file in the wrong way: double click the file to open it. 
 + 
 +Or, the installed version is too old. See above for minimum required VEConfigure / VE.Bus System Configurator tools version. 
 + 
 +=== mk2vsc-45 - Uploaded file does not contain settings data for the connected unit === 
 + 
 +Each inverter/charger has a unique numeric (serial) number; installed during production. This error shows in case the file sent was made for a different unit. 
 + 
 +Note that this error should never occur, error 47 or 48 will happen instead. 
 + 
 +=== mk2vsc-46 - Uploaded file does not match model and/or installed firmware version === 
 + 
 +To remotely update a systems settings, the full seven digit number in the file must match the system, worded differently: 
 + 
 +  * its not possible to take settings from a 3kVA and then upload it to a 5kVA model. 
 +  * its not possible to store settings from a system having version 479. Then update that system to 481, and then restore the settings by uploading that earlier saved file. Instead, use the merge function, see elsewhere in this manual. 
 + 
 + 
 +=== mk2vsc-47 - More than one unknown unit detected === 
 + 
 +This error applies to systems consisting if multiple units, ie. parallel-, split- or three-phase systems. 
 + 
 +Each inverter/charger has a unique numeric (serialnumber installed during production. This error shows in case two or more units in the system have serial number different from the file sent. 
 + 
 +In case one unit of such a system must be replaced, that can be done. The steps involved are: 
 + 
 +  - Read the configuration of the whole system (or use an existing Remote VEConfigure file) 
 +  - Physically replace the failed unit 
 +  - Write the configuration. At this step the system will automatically detect that a previous device is missing, and it will discover a new device with an unknown serial number. It will assume that the new device is a replacement, and write the settings accordingly. 
 +  - (optionally) Read the new configuration file and store in your records. 
 + 
 +Note that before starting above, make sure to update the new unit to the same version of VE.Bus firmware, which unfortunately can’t be done remotely. 
 + 
 +Solution: go onsite and use VE.Bus Quick Configure or VE.Bus System Configurator to reconfigure the system
 + 
 +=== mk2vsc-48 - Updating a single unit with another unit's settings is not possible, even if they are of the same type === 
 + 
 +Each inverter/charger has a unique numeric (serial) numberinstalled during production. This error shows in case the file sent was made or a different unit. 
 + 
 +There is a way: for the system that you want to configure, first do a Remote VEConfigure download, then open that file by double clicking it. Now in the menu of VEConfigure use Load settings option, and select the file of the system whose settings you want to copy. 
 + 
 +=== mk2vsc-55 - File section not found === 
 + 
 +Error mk2vsc-55 can happen for two reasons. In case it happens while doing a remote firmware update, it typically  the first one: 
 + 
 +1) After the firmware update, but still during stage 1, something went wrong. For example VRM lost connection to the site for too long because of bad internet. The firmware update will have completed, but an extra step is necessary to migrate the configuration from before the firmware update. See FAQ Q3 for details. 
 + 
 +2) The uploaded file is for a different product type. The model number, for example 2659, does not match. 
 + 
 +Note that from Venus OS v2.66 onwards, this error will not occur. Errors 45, 46, 47 and 48 have replaced it. 
 + 
 +=== mk2vsc-59 - file uploaded before merging in VE.Bus System Configurator === 
 + 
 +This error can show after uploading a settings file to the system using Remote VEConfigure. The error shows when the settings template made during a Remote firmware update was uploaded **without** first opening that in VE.Bus System Configurator. 
 + 
 +Solution: 
 + 
 +  - instead of uploading the file, open it on your computer with VE.Bus System Configurator. Typically done by simply double clicking the file. 
 +  - VE.Bus System Configurator will now process file the, and show a message when completed. 
 +  - finally, save it by closing VE.Configure. And upload the resulting file, which name will by _merged.rvms. 
 + 
 +===== 6. FAQ ===== 
 + 
 +==== Q1: What happens if the internet connection goes down during the process? ==== 
 + 
 +That depends. If it goes down only for a while; and then recovers within a few minutes after the Inverters are started up again; all will be fine. 
 + 
 +In case the internet outage is for another reason and/or takes too long, then this is what happens: 
 + 
 +The firmware update will complete without a problem. And the system will start-up again in the mode as described in chapter 3. 
 + 
 +What **will** go wrong is the process in which the old settings are converted and then made available for upload to the system. 
 + 
 +To recover, see FAQ Q3.
  
-At this moment the first stage is complete.+In case you're wondering how this can work without internet: thats because first the current configuration is retrieve from the system, then the new firmware file is being uploaded to the systemAnd only once thats done and checked for file integrity, the actual firmware update starts. 
 +==== Q2: How to see if a CCGX hardware version matches the required minimal version ====
  
-__Second stage__ +There are a few waysOne is by checking the serial number, it must be HQ1707 or newer17 is for 2017and the 07 is the week numberThe serial number is printed on a label on the back of the GX Deviceand in some cases also visible on the VRM Portalin the Device List.
-Now, you’ll need to open the provided file in VE.Bus System Configurator by double clicking it. Immediately, the settings will be converted to the new firmware version; and a popup will show in case anything needs double checkingWhen finishedclose the Configuratorit will prompt to save the file.+
  
-__Third stage__ +The other way is in the UI (either on the CCGX itselfor through Remote Console). Go to the Device List, then into the Multi or Quattro menu, then to the bottom, Device submenu, and scroll all the way to the bottom.
-On VRMgo to Device List -> Remote VEConfigure and there use the Upload feature to upload the settings. This will restore the charge current and the rest of the settings.+
  
-===== 5. FAQ =====+Here you'll see this menu:
  
-==== Q1What happens if the internet connection goes doen during the process====+{{ :venus-os:18520-mk2-version.png?nolink&400 |}}
  
-The firmware update will complete without problem, since the necessary files are uploaded to the GX Device *before* starting the firmware update.+It needs to say MK3. Above screenshot is from CCGX which hardware is too old to perform remote VE.Bus firmware updates.
  
-What will go wrong is preparing the .rvms file that contains the settings are well as information about the system after the firmware update. Normally a file will be available that when opened in VEConfigure will automatically be converted to the new firmware version. Now, since there was no internet connection anymore after the firmware update was completed, that file will only contain the settings from before the firmware update.+==== Q3: Merging files: how to recover the old settings when something went wrong ====
  
-Steps to recover: 
   - In VRM -> Device List -> Remote VEConfigure, and there click download.   - In VRM -> Device List -> Remote VEConfigure, and there click download.
-  - Open that file by double clicking it. In case of a single unit it will open in VEConfigure. For systems consisting of multiple units, it will be opened in VE.Bus System Configurator+  - Use the merge function in VE.Bus System Configurator:
-  - Click File -> Load settings, and select the first file. Ie the file prompted during the Firmware update process. +
-  - Now, the settings will automatically be converted to the new firmware version; and a popup will show in case anything needs double checking. +
-  - Close the file by exiting the application; a popup will prompt to save it. +
-  - On VRM, go to Device List -> Remote VEConfigure and there use the Upload feature to upload the settings.+
  
 +{{ :venus-os:ve.bus_system_configurator_merge_function.png?nolink&600 |}}