 :!: It is not possible to use a [[https://www.victronenergy.com/accessories/gx-gsm|GX GSM]], due to the integrated DHCP server in the Axiom MFD. :!: It is not possible to use a [[https://www.victronenergy.com/accessories/gx-gsm|GX GSM]], due to the integrated DHCP server in the Axiom MFD.
 +
 +**Note: As of Raymarine LightHouse v3.15, there is an option to toggle DHCP. Disabling this option does not mean that the Axiom MFD will work with third party network routers. See [[https://community.victronenergy.com/questions/45414/raymarine-victron-app.html?childToView=114335#comment-114335|this]] post on Victron Community for more information.**
 ===== 4. Configuration =====  ===== 4. Configuration ===== 
 On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)//. On the Victron GX Device, go to //Settings → Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)//.
Line 87: Line 89:
 === Raymarine only: data instances need to made unique === === Raymarine only: data instances need to made unique ===
  
-If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, then the Data instances of the Victron PGNs related to DC power need to changed to make each data instance unique.+If there are more than 1 (for example) SmartShunts in the NMEA2000 network, or a Solar Charger and a SmartShunt, or any other device that transmits the same type of PGNs, then the Data instances of those PGNs need to changed to make each data instance unique
 + 
 +Typically this concerns the Battery instance, used in the Battery Status and DC Detailed PGNs.
  
 See here for how to do that: [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|Changing NMEA2000 Instances]], section Data instances. This requires an [[https://actisense.com/products/ngt-1-nmea-2000-to-pc-interface/|Actisense NGT-1 NMEA to USB interface]]. See here for how to do that: [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|Changing NMEA2000 Instances]], section Data instances. This requires an [[https://actisense.com/products/ngt-1-nmea-2000-to-pc-interface/|Actisense NGT-1 NMEA to USB interface]].
  
 **Note**: this requirement of data instances being globally unique for a PGN is specific to Raymarine. Other brands do not require this. And, although perhaps besides the point, also the NMEA2000 standard does not require it. More specifically, it says: "Data instances shall be unique in the same PGNs transmitted by a device. Data instances shall not be globally unique on the network.". **Note**: this requirement of data instances being globally unique for a PGN is specific to Raymarine. Other brands do not require this. And, although perhaps besides the point, also the NMEA2000 standard does not require it. More specifically, it says: "Data instances shall be unique in the same PGNs transmitted by a device. Data instances shall not be globally unique on the network.".