venus-os:mfd-furuno
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
venus-os:mfd-furuno [2020-07-20 09:35] – [6. NMEA 2000] mbosma | venus-os:mfd-furuno [2020-07-29 17:42] – [6. NMEA 2000] mvader | ||
---|---|---|---|
Line 11: | Line 11: | ||
===== 2. Compatibility ===== | ===== 2. Compatibility ===== | ||
- | The MFD integration is compatible with the following | + | The MFD integration is compatible with the following |
* NavNet TZtouch3 TZT12F | * NavNet TZtouch3 TZT12F | ||
* NavNet TZtouch3 TZT16F | * NavNet TZtouch3 TZT16F | ||
* NavNet TZtouch3 TZT19F | * NavNet TZtouch3 TZT19F | ||
* Navnet TZtouch2 TZT2BB Black box | * Navnet TZtouch2 TZT2BB Black box | ||
- | NavNet TZtouch3 MFDs need at least software version v1.08. The Navnet TZtouch2 TZT2BB needs at least software version v7. | + | NavNet TZtouch3 MFDs need at least software version v1.08. The Navnet TZtouch2 TZT2BB needs at least software version v7.01. |
Note that the Navnet TZtouch2 TZT**L** models are **not** supported. | Note that the Navnet TZtouch2 TZT**L** models are **not** supported. | ||
Line 38: | Line 38: | ||
{{: | {{: | ||
- | It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router. | + | It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router, and that the router has its LAN IP addressing configured in the same subnet. |
:!: It is not possible to use a [[https:// | :!: It is not possible to use a [[https:// | ||
Line 56: | Line 56: | ||
===== 6. NMEA 2000 ===== | ===== 6. NMEA 2000 ===== | ||
- | The MFD can also be connected to the GX device using NMEA 2000, see [[https:// | + | The MFD can also be connected to the GX device using NMEA 2000, see [[https:// |
+ | |||
+ | This chapter documents the specifics when displaying Victron | ||
The MFD can be configured easily to display the data from the GX device. To display tank data, there is no need to change any instance. \\ | The MFD can be configured easily to display the data from the GX device. To display tank data, there is no need to change any instance. \\ | ||
Line 69: | Line 71: | ||
**Notes** | **Notes** | ||
- | - The current | + | - The tested Furuno |
- | - Due to a bug in the MFD firmware, a negative current is shown as '' | + | - Due to a bug in the MFD firmware, a negative |
venus-os/mfd-furuno.txt · Last modified: 2023-06-22 19:27 by sloges