 ===== 2. Compatibility ===== ===== 2. Compatibility =====
  
-The MFD integration is compatible with the following models:+The MFD integration is compatible with the following Furuno MFDs:
   * NavNet TZtouch3 TZT12F   * NavNet TZtouch3 TZT12F
   * NavNet TZtouch3 TZT16F   * NavNet TZtouch3 TZT16F
   * NavNet TZtouch3 TZT19F   * NavNet TZtouch3 TZT19F
   * Navnet TZtouch2 TZT2BB Black box   * Navnet TZtouch2 TZT2BB Black box
-NavNet TZtouch3 MFDs need at least software version v1.08. The Navnet TZtouch2 TZT2BB needs at least software version v7.+NavNet TZtouch3 MFDs need at least software version v1.08. The Navnet TZtouch2 TZT2BB needs at least software version v7.01.
  
 Note that the Navnet TZtouch2 TZT**L** models are **not** supported. Note that the Navnet TZtouch2 TZT**L** models are **not** supported.
Line 38: Line 38:
 {{:venus-os:furuno-ip-config.png?400|}} {{:venus-os:furuno-ip-config.png?400|}}
  
-It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router.+It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router, and that the router has its LAN IP addressing configured in the same subnet.
  
 :!: It is not possible to use a [[https://www.victronenergy.com/accessories/gx-gsm|GX GSM]]. :!: It is not possible to use a [[https://www.victronenergy.com/accessories/gx-gsm|GX GSM]].
Line 58: Line 58:
 The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]]. However, there is only limited support for NMEA 2000 PGNs sent from Victron equipment. The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]]. However, there is only limited support for NMEA 2000 PGNs sent from Victron equipment.
  
-The MFD can be configured easily to display the data from the GX device. There is no need to change any instance.+The MFD can be configured easily to display the data from the GX device. To display tank data, there is no need to change any instance. \\ 
 +In order to properly display battery/DC data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See here for how to do that: [[https://www.victronenergy.com/live/ve.can:changing_nmea2000_instances|Changing NMEA2000 Instances]], section Data instances. 
 To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names. To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names.
  
 The following Victron PGNs are supported: The following Victron PGNs are supported:
   * 127505 - Fluid level (tanks)   * 127505 - Fluid level (tanks)
-  * 127506 - DC Detailed Status (limited support); State-of-charge, Time-to-go +  * 127506 - DC Detailed Status (limited support); State-of-charge, Time-to-go <sup>(1)</sup> 
-  * 127508 - Battery Status (limited support); Voltage, Current+  * 127508 - Battery Status (limited support); Voltage, Current <sup>(1, 2)</sup> 
 + 
 +**Notes** 
 +  - The current MFD firmware only supports 4 batteries 
 +  - Due to a bug in the MFD firmware, a negative current is shown as ''---'' (three dashes) 
venus-os/mfd-furuno.txt · Last modified: 2023-06-22 19:27 by sloges