Line 58: | Line 58: | ||
The MFD can also be connected to the GX device using NMEA 2000, see [[https:// | The MFD can also be connected to the GX device using NMEA 2000, see [[https:// | ||
- | The MFD can be configured easily to display the data from the GX device. | + | The MFD can be configured easily to display the data from the GX device. |
+ | In order to properly display battery/DC data from Victron equipment, you need to change the data instances of the PGNs that are sent out. See here for how to do that: [[https:// | ||
To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names. | To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names. | ||
The following Victron PGNs are supported: | The following Victron PGNs are supported: | ||
* 127505 - Fluid level (tanks) | * 127505 - Fluid level (tanks) | ||
- | * 127506 - DC Detailed Status (limited support); State-of-charge, | + | * 127506 - DC Detailed Status (limited support); State-of-charge, |
- | * 127508 - Battery Status (limited support); Voltage, Current | + | * 127508 - Battery Status (limited support); Voltage, Current |
+ | |||
+ | **Notes** | ||
+ | - The current MFD firmware only supports 4 batteries | ||
+ | - Due to a bug in the MFD firmware, a negative current is shown as '' |