Line 38: Line 38:
 It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router. It is possible to connect a router to the same LAN; and that way connect the GX Device to the internet. Make sure the //Gateway// and //DNS Server// settings of the GX are set to the IP address of the router.
  
 +:!: It is not possible to use a [[https://www.victronenergy.com/accessories/gx-gsm|GX GSM]].
 ==== 4.2 Services configuration ==== ==== 4.2 Services configuration ====
 On the Victron GX Device, go to //Settings -> Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)//. On the Victron GX Device, go to //Settings -> Services//, and there enable both //MQTT on LAN (SSL)// and //MQTT on LAN (Plaintext)//.
Line 50: Line 51:
  
 {{youtube>0Mrk5Q4izvg}} {{youtube>0Mrk5Q4izvg}}
 +
 +===== 6. NMEA 2000 =====
 +
 +The MFD can also be connected to the GX device using NMEA 2000, see [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea_2000|NMEA2000 chapter in the main manual]]. However, there is only limited support for NMEA 2000 PGNs sent from Victron equipment.
 +
 +The MFD can be configured easily to display the data from the GX device. There is no need to change any instance.
 +To view NMEA 2000 devices on the MFD, go to //Settings > Initial Setup > Data Aquisition > Sensor List//. Here you can view basic information and change device instances and custom names.
 +
 +The following Victron PGNs are supported:
 +  * 127505 - Fluid level (tanks)
 +  * 127506 - DC Detailed Status (limited support); State-of-charge, Time-to-go
 +  * 127508 - Battery Status (limited support); Voltage, Current