User Tools

Site Tools


vebus_smart_dongle_manual

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
vebus_smart_dongle_manual [2018-09-21 13:07] – [Introduction] justin_tyers_live_a_cvebus_smart_dongle_manual [2022-09-13 14:44] (current) – Old manual deleted and linked to product download page stefanie
Line 1: Line 1:
-====== VE.Bus Smart Dongle manual ====== +The old VE.Bus Smart Dongle manual have been removedYou can find the new manual here: [[https://www.victronenergy.com/panel-systems-remote-monitoring/ve-bus-smart-dongle#manuals]]
- +
-Work in progress. This page contains input for the user manual +
-{{:benh7ta_79897301-690x277.png?400|}} +
-===== Introduction ===== +
- +
-The VE.Bus Smart dongle is a Bluetooth Smart enabled VE.Bus interface, with battery temperature-and-voltage sensor. It communicates system information straight to your smart phone - using the free-to-use //VictronConnect// app. +
- +
-When used with Multi- inverter/chargers the dongle provides //on-battery// temperature and voltage sensing capabilities - allowing compensation for possible cable losses which can occur during charging and discharging; and it allows temperature-compensation.  On MultiPlus-II models the dongle is, at present, the //only// way to add an "on-battery" sensing capability. +
- +
-The dongle can be used in systems with or without a Venus device - such as the CCGX. In systems //with// a Venus device, the dongle will not override temperature and voltage information already being supplied by the Venus device - in this rôle the dongle will provide live-information via its VictronConnect interface; and it will provide no-internet firmware updates.  +
- +
-When the dongle is used in systems which //do not// have a Venus device, the dongle's voltage and temperature data becomes the primary source of that information, and can be used by other connected devices for voltage compensationThus, the VE.Bus Smart dongle can be part of a VE.Smart network ...sending voltage and temperature data to other Smart network devices. +
-  +
-The VE.Bus Smart dongle is able to receive its temperature data in two ways: The default source of information is the dongle's on-board temperature sensorwhen the dongle is mounted directly onto the battery case (using its adhesive attachment) it will sense the battery temperature from the battery casing. However,improved battery temperature sensing is available by using an optional //battery-terminal// mounted sensor. If connected, the dongle will automatically detect this sensor, and use its temperature readings instead.  +
- +
-===== What's in the box =====  +
-  - VE.Bus Smart Dongle +
-  - Red battery (+) connection wire with 10mm eyelet and inline fuse. +
-  - Black battery (-) connection wire with 10mm eyelet +
-  - Connector block with screw terminals. +
-  +
-Optional accessories : +
-  - External battery-terminal mounted temperature sensor ([[https://www.victronenergy.com/accessories/temperature-sensor-for-bmv-702|ASS000100000]]). //(NOTE: Currently the temperature sensor is shipped with a label "CAUTION: BMV702 only!". This caution can be ignored for the VE.Bus Smart dongle)// +
-{{:1530773828_upload_products_260_260-313_329_20170712114111.png?400|}} +
-===== Installation ===== +
- +
-Installation without battery sensor: +
-  Connect the red connection wire to the B+ input on the connection block +
-  Connect the black connection wire to the B- input on the connection block +
-  - Connect the two eyelets to your battery terminal. Red wire eyelet on bat+ , black wire eyelet on bat- +
-  - Mount the dongle on or near the battery using the dongle's adhesive mounting. If mounted near the battery, screws can be used.  +
-  - Plug the connector block into the dongle.  +
-  - Connect the dongle to the Multi's Ve.Bus interface, using a standard RJ45 UTP cable +
- +
-Installation with battery terminal temperature sensor:\\ +
-The battery temperature sensor replaces the included red battery(+) connection wire. +
-  - Connect the temperature sensor's red  connection wire to the B+ input on the connection block +
-  - Connect the temperature sensor's black connection wire to the T- input on the connection block +
-  - Connect the black connection wire to the B- input on the connection block +
-  - Connect the two eyelets to your battery terminal. Red wire eyelet on bat+ , black wire eyelet on bat- +
-  - Mount the dongle on or near the battery using the dongle's adhesive mounting. If mounted near the battery, screws can be used.  +
-  - Plug the connector block into the dongle.  +
-  - Connect the dongle to the Multi's Ve.Bus interface, using a standard RJ45 UTP cable +
- +
-===== System requirements ===== +
- +
-**Multi firmware versions before 415 are not supported** +
- +
-^ Function                                            ^ Minimum Multi firmware version ^ Note ^ +
-| Battery voltage and temperature sense               | 419                            |      | +
-| Input current limit and on/off/charger only control | 415                            | Not supported when a DMC and/or VeBus BMS is installed |  +
- +
-===== LED Status codes ===== +
- +
-//Ve.Bus Smart// has two LEDs: a Bluetooth status LED (blue), and an Error LED (red).  +
- +
-On power-up, the Bluetooth LED will be slow-blinking - indicating that the device is ready to accept a Bluetooth connection. +
- +
-If both LEDs remain illuminated, something is wrong with the //Ve.Bus Smart// unit (Hardware error). +
- +
-When the LEDs are alternating quickly for more than 30 seconds, the //Ve.Bus Smart// is in firmware update mode and will need to complete the update before it can be used. Firmware updates are performed (where necessary) after connecting to VictronConnect. +
- +
- +
-^ Blue LED       ^ Red LED          ^ Ve.Bus Smart dongle state ^ Connection State ^ Remark +
-| On             | On               | Not functional            | Disabled         | Hardware error. \\ //Ve.Bus Smart// will not be visible in VictronConnect and \\ it will not transmit battery temperature and voltage data to the Multi | +
-| Slow blinking  | Off              | Operational               | Not connected    |         | +
-| On             | Off              | Operational               | Connected        |         | +
-| Fast blinking  | Fast blinking    | Firmware update           | Not connected    | Red and Blue LED Alternating +
-| On             | Slow blinking    | Firmware update           | Connected        |         | +
-| On             | Faster blinking  | Firmware update           | Uploading        |         | +
-| Fast blinking  | Off              | Firmware update           | Programming      |         | +
- +
-===== Modes of operation ==== +
-As indicated in the introduction the dongle can operate in "primary" or "secondary" mode. The mode depends on the availability of a Venus device. Due to restrictions in the VeBus communication protocol only one device can access data such as power readings.A Venus device has priority over the dongle and should always be able to access all data. When power is applied to the dongle - or after a firmware update - the dongle will startup in "secondary" mode. VE.Bus communication will be monitored for 30 seconds. If during this time no Venus device is detected the dongle will switch to "primary" mode and all supported data will be available. While switching modes VictronConnect will temporarily indicate an "unknown" VE.Bus state. The dongle continuously monitors Venus device activity on the VE.Bus. As soon as Venus device is detected it will switch back to "secondary" mode. +
- +
-Likewise the dongle also monitors VE.Bus communication in order to discover if a Venus device supplies the Multi with battery voltage and temperature data. It takes around 4 minutes after power on, or reset, before the dongle decides whether or not to transmit the battery voltage and temperature.  +
- +
-When no Multi is connected the dongle will be shown as VeBus Smart dongle only. In this case the dongle can be used as a Voltage/Temperature sensor. VictronConnect will display the dongle in the device list. +
-It takes a bit of time before a Multi is detected. When the dongle detects a Multi, it will show the Multi product ID. VictonConnect will than display the Multi in the Device list. +
-Shortly after updating the firmware in VictronConnect only the dongle will show up in the device list. If connected, a re-scan will reveal the Multi. +
- +
- +
-===== Troubleshooting ===== +
- +
-See both the [[victronconnect:start|VictronConnect manual]] and the [[victronconnect:ve-smart-networking|VE.Smart Network manual]]. +
- +
  
  
vebus_smart_dongle_manual.1537528038.txt.gz · Last modified: 2018-09-21 13:07 by justin_tyers_live_a_c

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki