Line 4: Line 4:
  
   * Dynamic Cut-off feature is disabled by default   * Dynamic Cut-off feature is disabled by default
-  * Use [[victronconnect:​start|VictronConnect]] to enable and configure Dynamic Cut-off. Necessary pages were added in VictronConnect v1.7 +  * Use [[victronconnect:​start|VictronConnect]] to enable and configure Dynamic Cut-off 
-  * The default cut-off voltages are the same as used in [[system_integration:hub4_grid_parallel|Hub-4 in VEConfigure]] +  * The default cut-off voltages are the same as used in our [[ess:start|ESS Systems]] 
-  * Don’t ​use Dynamic Cut-off in an installation that also has other loads connected to the same battery: the battery voltage will drop because of the extra load, but the Dynamic Cut-off algorithm in the Inverter is not aware of that load: hence the Inverter will shut down too early with an under voltage alarm.+  * Do not use Dynamic Cut-off in an installation that also has other loads connected to the same battery: the battery voltage will drop because of the extra load, but the Dynamic Cut-off algorithm in the Inverter is not aware of that load: hence the Inverter will shut down too early with an under voltage alarm.
  
 ===== Details ===== ===== Details =====
Line 16: Line 16:
  
 The picture below shows the default '​Discharge'​ vs. 'DC input low shut-down voltage'​ curve for the different battery types. The curve can be adjusted in the assistant. \\ {{:​system_integration:​dynamic_cutoff.png?​nolink}} The picture below shows the default '​Discharge'​ vs. 'DC input low shut-down voltage'​ curve for the different battery types. The curve can be adjusted in the assistant. \\ {{:​system_integration:​dynamic_cutoff.png?​nolink}}
 +
  