ve.can:nmea-2000:start [2021-03-15 20:07] – [2.3 Tank monitoring] mvaderve.can:nmea-2000:start [2022-03-16 12:19] (current) – [3.4 DC Voltage compatibility] stefanie
Line 4: Line 4:
  
 ==== 1.1 Summary ==== ==== 1.1 Summary ====
-This document explains how to integrate a Victron system onto a Marine MFD, such as those from Garmin, Raymarine, the Navico brands B&G, Simrad and Lowrance as well as Furuno other brands.+This document explains how to integrate a Victron system onto a marine MFD also known as a chart plotter. Compatible brands include Garmin, Raymarine, the Navico brands B&G, Simrad and Lowrance as well as Furuno.
  
-There are multiple options, and how to best integrate depends on the customer requirements, MFD brand and model as well as used Victron components.+There are multiple options, and how to best integrate depends on the customer requirements, preferred MFD brand and model as well as used Victron components.
  
 Make sure to closely read this full document to find the best method for your type of system. Make sure to closely read this full document to find the best method for your type of system.
  
-{{:ve.can:nmea-2000:image_hml5_nmea2k_arrows.png?direct&500 |}}//Picture showing the two integration options, NMEA2000 and HTML5 App. Click to see full size.//+{{:ve.can:nmea-2000:image_hml5_nmea2k_arrows.png?direct&500 |}}//Picture showing the two integration options, NMEA2000 and HTML5 App. Click to see full size and see the difference between the two.//
 ==== 1.2 What is NMEA 2000? ==== ==== 1.2 What is NMEA 2000? ====
-NMEA2000 is a communications standard used for connecting marine sensors and display units within ships and boats.+NMEA 2000 is a communications standard used for connecting marine sensors and display units within ships and boats.
  
 Victron Energy is a member of the NMEA 2000 organisation, and we have several of our products certified by NMEA 2000. Victron Energy is a member of the NMEA 2000 organisation, and we have several of our products certified by NMEA 2000.
Line 52: Line 52:
 ==== 2.2 Products with a VE.Can port ==== ==== 2.2 Products with a VE.Can port ====
  
-Some of our products feature a VE.Can port; which can be directly connected to the NMEA 2000 network. No electronic converter is necessary. The conversion cable required is the [[https://nocache.victronenergy.com/accessories/ve-can-to-nmea2000-micro-c-male|VE.Can to NMEA2000 cable]].+All Victron products that feature a VE.Can port can be directly connected to the NMEA 2000 network, using the [[https://nocache.victronenergy.com/accessories/ve-can-to-nmea2000-micro-c-male|VE.Can to NMEA2000 cable]].
  
-These products include our Skylla-i battery chargers, Lynx Shunt VE.Can battery monitor as well as the Skylla IP65 battery charger series.+  * Skylla-i 24V Battery Chargers 
 +  * Skylla IP65 Battery Chargers 
 +  * Lynx Shunt VE.Can Battery Monitor 
 +  * Lynx Smart BMS 
 +  * SmartSolar MPPT Solar Chargers with VE.Can communications port
  
-==== 2.3 Tank monitoring ====+{{ :ve.can:nmea-2000:schema_nmea2000-vecan_mppt-skylla_nov_2016.png?nolink&500 |}}
  
-The GX devices can measure tank levels, and make the resulting data available on the NMEA2000 network.+==== 2.3 Tank monitoring integration ====
  
-Also, they can read tank leven data from the network, when there are other tank senders connected. It will be shows it on the Victron screens as well as transmitted to the VRM Portal for remote monitoring.+The GX devices can measure tank levels, and make the resulting data available on the NMEA2000 network. Also, they can read tank level data from the N2K network.
  
 Below sections explain the details of each integration type. Below sections explain the details of each integration type.
Line 82: Line 86:
 Compatible tank senders are listed in the [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/installation.html#UUID-9813aef4-8178-293b-12ef-0048b064271f|GX manual, installation chapter]]. Compatible tank senders are listed in the [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/installation.html#UUID-9813aef4-8178-293b-12ef-0048b064271f|GX manual, installation chapter]].
  
-TODO ADD SCREENSHOTS+{{ :ve.can:nmea-2000:gx_touch_tanks_overview.png?direct&400 |}}
  
-==== 2.4 Using our converter interfaces (DEPRECATED!) ====+//Above picture: GX Touch 50, showing multiple tank levels. Coming from either the NMEA2000 network, directly connected resistive tank senders or via the GX Tank 140 accessory.// 
 + 
 +//Below screenshot shows a similar system, but then on the [[https://vrm.victronenergy.com|VRM Portal]].// 
 + 
 +{{ :ve.can:nmea-2000:vrm_tanks.png?direct&800 |}} 
 + 
 +==== 2.4 NMEA 2000 GPS integration ==== 
 + 
 +Our GX devices can read location, altitude, speed and course from the NMEA2000 network. For details, see the GX manual. 
 + 
 +Note the other way around does not work. A GX Device which has a USB GPS installed does not emit GPS data out onto the NMEA2000 network as part of the NMEA2000-out function. 
 + 
 +==== 2.5 Using our converter interfaces (DEPRECATED!) ====
  
   * [[https://www.victronenergy.com/accessories/ve-bus-to-nmea2000-interface|VE.Bus to NMEA 2000 interface]]    * [[https://www.victronenergy.com/accessories/ve-bus-to-nmea2000-interface|VE.Bus to NMEA 2000 interface]] 
Line 91: Line 107:
 Note that the use of both those interfaces is deprecated. Use a GX device instead. Note that the use of both those interfaces is deprecated. Use a GX device instead.
  
 +===== 3. NMEA2000 Details =====
  
 +==== 3.1 PGN Lists ====
  
 +Refer to our [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Datacommunication whitepaper]], page 8 and beyond, for a list of Victron products and their supported PGNs.
  
 +==== 3.2 NMEA 2000 instancing ====
  
-===== 3Varia =====+NMEA 2000 Instances are used to identify multiple similar products connected on the same network.
  
 +There are several types of instances, the most important ones being the **Device instance** as well as the **Data instances**.
  
-==== 3.1 VE.Can products (Skylla-i, Skylla-IP44, Lynx Shunt, Lynx Ion+Shunt and more) ====+More information about instances is in [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/marine-mfd-integration-by-nmea2000.html#UUID-97031b2e-6b21-dd88-56ee-31c0aaca9183|the NMEA2000 chapter in the GX manual]].
  
-Since the Victron VE.Can communication protocol is based on N2K, the following products can all be connected directly to a N2K network. The only thing necessary is a plug converter: the [[https://www.victronenergy.com/cables/ve-can-to-nmea2000-cable|VE.Can to NMEA 2000 cable]].+=== What settings need to be made? For example instances? ===
  
-  * Skylla-i 24V Battery Chargers +That is a commonly asked questionThe answer depends on the used brand of MFD
-  * Skylla IP44 Battery Chargers +
-  * Lynx Shunt Battery Monitors +
-  * Lynx Ion + Shunt all models +
-  * SmartSolar MPPT Solar Chargers with VE.Can communications port +
-{{ :ve.can:nmea-2000:schema_nmea2000-vecan_mppt-skylla_nov_2016.png?nolink&700 |}}+
  
 +For **Garmin, Furuno, Maretron and Navico (B&G, Lowrance, Simrad) systems**: none. No instances, also not data instances such as the DC Detailed instance, need to be changed. It all works out of the box, other than configuring what field to show where on the MFD.
  
 +For **Raymarine**, you might need to do some configuration: for systems with a SmartShunt and a SolarCharger, or multiple SmartShunts, or a Lynx Smart BMS, the data instances need to be configured to be unique. More information about that in the [[https://www.victronenergy.com/live/venus-os:mfd-raymarine|Victron & Raymarine document]], in the last chapter.
  
-==== 3.2 Raymarine & EmpirBus ====+==== 3.3 Terminators and network layout ====
  
-Besides using NMEA 2000 and/or the Lighthouse Appintegration onto Raymarine MFDs can also be done with an [[http://www.trigentic.com/#nxt-mcu|Empirbus NXT MCU ]]. Though both are connected to the same N2K network, the NXT MCU translates the N2K PGNs originating from the Victron equipment into Raymarine proprietary messages.+A N2K CAN-bus network needs to be laid out as in a backbone configuration, using drop cables to connect to each device. Alsothere should be only two terminators in the network. Therefore:
  
-In the [[http://www.empirbus.com/clickOnce/EmpirBusStudio-Demo/|EmpirBus Studio software]] you will find dedicated Victron building blocks than can be drawn onto the diagram.+  * Use the NMEA 2000 cable as the backbone. 
 +  * Run a separate drop cable separately to each Victron device [[https://www.victronenergy.com/accessories/ve-can-to-nmea2000-micro-c-male|VE.Can to NMEA 2000 cable]] 
 +  * Only terminate the NMEA 2000 backbone. Do not install a terminator in any of the VE.Can ports on the Victron products.
  
-Next, use the [[http://www.trigentic.com/#empirbus-graphic|EmpirBus Graphical tool]] to design the pages for on the Raymarine MFDs. +Or:
  
-The EmpirBus system requires the data instance of battery status and dc detailed status to be unique when using multiple sources([[ve.can:changing_nmea2000_instances#changing_a_data_instance|how to change data instances]])+  * Have the N2K network on one side, with one terminatorOn the other end, change to the Victron network, with also one (Victronterminator at the end.
  
 +The first option is more aligned with the official N2K method. But, in case of multiple Victron products that need to be connected to the N2K network, will require more wire runs and definitively more NMEA2000 to VE.Can conversion cables.
 +==== 3.4 DC Voltage compatibility ====
  
-==== 3.3 Maretron ====+The Victron VE.Can network accepts 9 to 70VDC.
  
-All data sent out by Victron devices can be picked up by the Maretron MFDs & softwareSee the [[http://www.maretron.com/products/N2KView.php|Maretron N2KView® vessel monitoring and control software]].+The NMEA-2000 network used to be 9 to 16VDC, which is, or will be, expanded to also include 24VWhich means that some NMEA-2000 devices are 9 to 16VDC, some are 9 to 30VDC, and some allow higher voltages.
  
-===== 4NMEA2000 PGN overview =====+Also, the Victron VE.Can network will (in most cases) be powered with battery voltage. So for a 48V system, the voltage on the VE.Can network **exceeds** the NMEA-2000 accepted voltage levels.
  
-Refer to our [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Datacommunication whitepaper]], page 8 and beyond, for a list of Victron products and their supported PGNs.+Therefore, it is important to **not** connect those power cables.
  
-===== 5FAQ =====+The Victron cable used to connect both networks together, the [[https://www.victronenergy.com/accessories/ve-can-to-nmea2000-micro-c-male|VE.Can to NMEA 2000 cable]], has a removable fuse which is to be removed in case separation is necessary. A printed warning label is attached to the cable to warn about this.
  
-Note that there are many more generic frequently asked questions answered in the [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication white paper]].+==== 3.5 Further reading on Victron and NMEA 2000 ====
  
-==== Q1What about instances? Device instancesdata instances? ====+  * [[https://www.victronenergy.com/upload/documents/Whitepaper-Data-communication-with-Victron-Energy-products_EN.pdf|Data communication white paper]] 
 +  * [[https://www.victronenergy.com/media/pg/Cerbo_GX/en/marine-mfd-integration-by-nmea2000.html|Cerbo GX manualNMEA 2000 chapter]] 
 +  * [[https://community.victronenergy.com/topics/NMEA%202000%20-%20N2K.html|NMEA2000 related discussions on Victron Community]]
  
-See [[ve.can:changing_nmea2000_instances|]] for details on that.+===== 4Varia =====
  
-==== Q2: What about terminators and network layout? ====+==== 4.1 Raymarine & EmpirBus ====
  
-A N2K CAN bus network needs to be laid out as in a backbone configuration, using drop cables to connect to each device. Alsothere should be only two terminators in the network. Therefore:+Besides using NMEA 2000 and/or the Lighthouse Appintegration onto Raymarine MFDs can also be done with an [[https://www.empirbus.com/#nxt-mcu|Empirbus NXT MCU ]]. Though both are connected to the same N2K network, the NXT MCU translates the N2K PGNs originating from the Victron equipment into Raymarine proprietary messages.
  
-  * Use the NMEA 2000 cable as the backbone. +In the [[https://www.empirbus.com/#empirbus-studio|EmpirBus Studio software]] you will find dedicated Victron building blocks than can be drawn onto the diagram. 
-  * Run a separate drop cable separately to each Victron device. The drop cable will be one of these three products: + 
-    * [[https://www.victronenergy.com/accessories/ve-bus-to-nmea2000-interface|VE.Bus to NMEA 2000 interface]] +Next, use the [[http://www.empirbus.com/#empirbus-graphic|EmpirBus Graphical tool]] to design the pages for on the Raymarine MFDs 
-    [[https://www.victronenergy.com/accessories/ve-direct-to-nmea2000-interface|VE.Direct to NMEA 2000 interface]] + 
-    [[https://nocache.victronenergy.com/accessories/ve-can-to-nmea2000-micro-c-male|VE.Can to NMEA 2000 cable]] +The EmpirBus system requires the data instance of battery status and dc detailed status to be unique when using multiple sources. ([[ve.can:changing_nmea2000_instances#changing_a_data_instance|how to change data instances]]) 
-  * Only terminate the NMEA 2000 backbone, do not terminate on the VE.Can side.+ 
 +==== 4.2 Maretron ==== 
 + 
 +All data sent out by Victron devices on the N2K network can be picked up by the Maretron MFDs & software. See the [[http://www.maretron.com/products/N2KView.php|Maretron N2KView® vessel monitoring and control software]]. 
 + 
 +===== 5FAQ ===== 
 + 
 +=== Q1: Can/must both Ethernet and and N2K connection be made between Victron GX and MFD? === 
 + 
 +Both can be made at the same time.
  
-==== Q3: What PGNs does a GX Device transmit on N2K? ====+Ethernet is needed to get the MFD App, as explained above.
  
-See the [[https://www.victronenergy.com/live/ccgx:start#marine_mfd_integration_by_nmea2000|NMEA 2000 chapter in the CCGX manual]] for details.+And an N2K connection is needed to get data to show in other fields on the MFD.
  
-==== Q4: Can integration onto Raymarine displays also be done without Empirbus NXT? ====+See annotated screenshot above for which is what.
  
-Yes, see [[https://www.victronenergy.com/panel-systems-remote-monitoring/marine%20mfd%20gx%20integration%20-%20raymarine|the Raymarine integration page on our website]]. 
ve.can/nmea-2000/start.1615835233.txt.gz · Last modified: 2021-03-15 20:07 by mvader