ve.bus:ve.bus_error_codes [2019-06-11 10:20]
mvader [General]
ve.bus:ve.bus_error_codes [2019-06-11 12:17] (current)
mvader [Error 24 - Switch-over system protection initiated]
Line 176: Line 176:
   * The AC input voltage slowly drops before it is being rejected by the Multis. Typically happens in installations with a generator. Especially when combined with AC loads that increase their current draw when the AC voltage drops: by the time that the inverter/​charger initiates the disconnect, the current through the relays has increased well beyond the ratings, and is too high to open them.\\ __Solution__:​ Make the Multis or Quattros disconnect earlier: increase lower limit of AC input voltage in VEConfigure3. For example to 210 VAC. The factory setting is 180 VAC.   * The AC input voltage slowly drops before it is being rejected by the Multis. Typically happens in installations with a generator. Especially when combined with AC loads that increase their current draw when the AC voltage drops: by the time that the inverter/​charger initiates the disconnect, the current through the relays has increased well beyond the ratings, and is too high to open them.\\ __Solution__:​ Make the Multis or Quattros disconnect earlier: increase lower limit of AC input voltage in VEConfigure3. For example to 210 VAC. The factory setting is 180 VAC.
   * The back-feed relay has a hardware failure \\ __Solution__:​ Replace faulty unit.   * The back-feed relay has a hardware failure \\ __Solution__:​ Replace faulty unit.
-  * The related current measurement circuit is faulty. \\ __Solution__: ​replace ​faulty unit.+  * The related current measurement circuit is faulty. \\ __Solution__: ​Replace ​faulty unit.
  
 __Diagnosing a parallel, multi or split-phase system?__ __Diagnosing a parallel, multi or split-phase system?__