multiplus_faq
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | Next revisionBoth sides next revision | ||
multiplus_faq [2019-10-17 13:48] – [3.1 Derating of the power factor] guystewart | multiplus_faq [2019-12-01 23:50] – updated ve-configure to veconfigure guy_stewart | ||
---|---|---|---|
Line 59: | Line 59: | ||
Warning: changing these settings will allow to feed-through current that may be of insufficient quality for the electrical requirements of your equipment. | Warning: changing these settings will allow to feed-through current that may be of insufficient quality for the electrical requirements of your equipment. | ||
- | For information on VE-Configure | + | For information on VEConfigure |
- | ====== 1. In the “Grid” tab of VE-Configure: ====== | + | ====== 1. In the “Grid” tab of VEConfigure: ====== |
| | ||
Line 126: | Line 126: | ||
- | ====== 2. In the “General” tab of VE-Configure: ====== | + | ====== 2. In the “General” tab of VEConfigure: ====== |
{{:: | {{:: | ||
Line 141: | Line 141: | ||
===== 2.2 AC Input Current Limit ===== | ===== 2.2 AC Input Current Limit ===== | ||
- | The charger on the Multiplus is very powerful. If you have an existing generator that is not able to supply the maximum charging current of the Multi, you will need to adjust the AC Input Current Limit in the General Tab of VE-Configure. | + | The charger on the Multiplus is very powerful. If you have an existing generator that is not able to supply the maximum charging current of the Multi, you will need to adjust the AC Input Current Limit in the General Tab of VEConfigure. |
A reasonable starting point for the AC Current input limit is 80% of the generator capacity in Watts. For example: | A reasonable starting point for the AC Current input limit is 80% of the generator capacity in Watts. For example: | ||
Line 162: | Line 162: | ||
- | ====== 3. In the " | + | ====== 3. In the " |
{{: | {{: | ||
Line 179: | Line 179: | ||
**Important note:** | **Important note:** | ||
- | A detailed description of all settings is available in the VE-Configure | + | A detailed description of all settings is available in the VEConfigure |
- | ====== 4. In the “Inverter” tab of VE-Configure: ====== | + | ====== 4. In the “Inverter” tab of VEConfigure: ====== |
===== 4.1 PowerAssist ===== | ===== 4.1 PowerAssist ===== | ||
Line 197: | Line 197: | ||
Try with a different generator. | Try with a different generator. | ||
- | There can be issues with generators with Residual Current Devices (RCD' | + | As troubleshooting and correcting these faults have serious safety implications, |
+ | There can be issues with generators with Residual Current Devices (RCD' | ||
+ | |||
+ | Simplify the AC wiring, With everything safely shut down and tested for voltage, disconnect the AC-Output active, neutral and earth. Direct wire in the generator connections, | ||
If there is still no connection, contact your dealer or distributor. Tell them the steps that you have taken already to attempt to get it to work and they can help from there. | If there is still no connection, contact your dealer or distributor. Tell them the steps that you have taken already to attempt to get it to work and they can help from there. |
multiplus_faq.txt · Last modified: 2023-02-16 01:50 by guy_stewart