mppt_pv_short_relay_reset
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
mppt_pv_short_relay_reset [2023-01-11 10:59] – [Reset latching relay] tabreu | mppt_pv_short_relay_reset [2023-04-18 09:34] (current) – [Reset latching relay] tabreu | ||
---|---|---|---|
Line 11: | Line 11: | ||
==== When to perform this procedure? ==== | ==== When to perform this procedure? ==== | ||
- | Connecting | + | Applying |
Recovering from such mistriggers is the purpose of the here documented reset feature. | Recovering from such mistriggers is the purpose of the here documented reset feature. | ||
Line 18: | Line 18: | ||
==== Reset latching relay ==== | ==== Reset latching relay ==== | ||
To recover from such failure, the below reset procedure must be followed. | To recover from such failure, the below reset procedure must be followed. | ||
- | - Power the solar charger through its battery terminals with a 12V battery or bench power supply set to 12V. | + | |
- | - Leave the PV Input terminals | + | |
- Make sure no error 80 to 83 is active. If it is active, power cycle the unit. | - Make sure no error 80 to 83 is active. If it is active, power cycle the unit. | ||
- Open VictronConnect and navigate to the Product settings menu. There the PV Short reset feature is shown.{{ : | - Open VictronConnect and navigate to the Product settings menu. There the PV Short reset feature is shown.{{ : |
mppt_pv_short_relay_reset.txt · Last modified: 2023-04-18 09:34 by tabreu