 ====== MPPT Solar Charger PV Short Relay Reset ====== ====== MPPT Solar Charger PV Short Relay Reset ======
- 
-DRAFT 
  
 This document explains how to perform a reset of an internal protection built into the Smart Solar Charger 250/100. Called the PV Short Relay. This document explains how to perform a reset of an internal protection built into the Smart Solar Charger 250/100. Called the PV Short Relay.
Line 13: Line 11:
 ==== When to perform this procedure? ==== ==== When to perform this procedure? ====
  
-Connecting a Solar Charger that is configured for 12V to a 48V battery, and then connecting the PV Array, can cause the protection to "mistrigger". Meaning that the charger sees an over voltage, and as such assumes that there is an internal fault and then engages the latching protection.+Applying higher battery voltage than configured in the Solar Charger (eg. 48V battery to a 12, 24 or 36V configured charger), and then connecting the PV Array, can cause the protection to mistrigger. Meaning that the charger sees an over voltage, and as such assumes that there is an internal fault and then engages the latching protection.
  
 Recovering from such mistriggers is the purpose of the here documented reset feature. Recovering from such mistriggers is the purpose of the here documented reset feature.
  
-DRAFT: Follow below procedure only if (a) the charger is not measuring any PV voltage when it should (i.e. during the day, with sun shinning, and all connections are ok). (b) the charger no longer charges the battery and measuring the PV Input with a MultiMeter in resistance mode shows a few Ohms or lower. (c) the charger no longer charges an error 80 to 87 is/was shown.+Follow below procedure only if (a) the charger is not measuring any PV voltage when it should (i.e. during the day, with sun shinning, and all connections are ok). (b) the charger no longer charges the battery and measuring the PV Input with a MultiMeter in resistance mode shows a few Ohms or lower. (c ) the charger no longer charges an error 80 to 87 is/was shown.
 ==== Reset latching relay ==== ==== Reset latching relay ====
 To recover from such failure, the below reset procedure must be followed.  To recover from such failure, the below reset procedure must be followed. 
 +  - Disconnect the PV Input terminals.
   - Power the solar charger through its battery terminals with a 12V battery or bench power supply set to 12V.   - Power the solar charger through its battery terminals with a 12V battery or bench power supply set to 12V.
-  - Leave the PV Input terminals disconnected+  - Make sure no error 80 to 83 is active. If it is active, power cycle the unit
-  - Open VictronConnect and navigate to the Product settings menu. There the PV Short reset feature is shown.{{ :drafts:mppt_pv_short_relay_reset.png?600 |}} Note that the feature only shows when (a) the connected units features the protection, ie. 250/100 VE.Can model, HQ2150 and later; (b) requires the battery voltage to be between 10 and 15V; (c) requires VictronConnect v.580 or later and (d) requires firmware version v3.12 or later to be installed on the Solar Charger.+  - Open VictronConnect and navigate to the Product settings menu. There the PV Short reset feature is shown.{{ :drafts:mppt_pv_short_relay_reset.png?600 |}} Note that the feature only shows when (a) the connected units features the protection, ie. 250/100 VE.Can model, HQ2150 and later; (b) requires the battery voltage to be between 10 and 15V; (c ) requires VictronConnect v.580 or later(d) requires firmware version v3.12 or later to be installed on the Solar Charger and (e) no error 80 to 83 is active.
   - Then click the RESET button. It will gray out for a few seconds and return blue. A click might be heard.   - Then click the RESET button. It will gray out for a few seconds and return blue. A click might be heard.
 For the SmartSolar VE.Can MPPT 250/100 with a serial number between HQ2150 and HQ2250, the reset procedure – unfortunately – often does not work. In this case, contact your dealer for replacing the MPPT under warranty. For the SmartSolar VE.Can MPPT 250/100 with a serial number between HQ2150 and HQ2250, the reset procedure – unfortunately – often does not work. In this case, contact your dealer for replacing the MPPT under warranty.