Next revisionBoth sides next revision
mppt-error-codes [2019-07-12 16:44] – [Err 68 - Network misconfigured] mvadermppt-error-codes [2019-11-30 10:10] – [Err 119 - Settings data lost] boekel
Line 68: Line 68:
  
 Disconnect all wires, and then reconnect all wires. If the error persists the charge controller is probably faulty. Disconnect all wires, and then reconnect all wires. If the error persists the charge controller is probably faulty.
 +
 +Note that this error was introduced in v1.36. So when doing an update, it might look like the firmware update caused this issue; but it doesn't. The Solar charger was then already not performing 100% before the update; updating to v1.36 or later merely made the issue more visible. The unit needs to be replaced.
  
 ==== Err 33 - PV over-voltage ==== ==== Err 33 - PV over-voltage ====
Line 146: Line 148:
  
 This error will not auto-reset. To get it working again: This error will not auto-reset. To get it working again:
-  - First, restore it to factory defaults.+  - First, restore it to factory defaults. (top right in Victron Connect, click on the three dots)
   - Disconnect the charge controller from all power-sources   - Disconnect the charge controller from all power-sources
   - wait 3 minutes, and power up again.   - wait 3 minutes, and power up again.