mppt-error-codes [2019-07-05 06:43]
mvader [Err 20 - Maximum Bulk-time exceeded]
mppt-error-codes [2019-07-12 16:44]
mvader [Err 68 - Network misconfigured]
Line 121: Line 121:
 Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can. Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can.
  
-The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https://​www.victronenergy.com/​live/​victronconnect:​ve-smart-networking|wireless VE.Smart protocol]]; and at the same time it is part of an [[https://​www.victronenergy.com/​live/​ess:​start|Energy Storage System (ESS)]]. Or its used in an installation with an intelligent battery. In all those cases, the charger is being externally controlled, and should not at the same time be configured for parallel operation.+The typical reason for the error to show is that the charger is configured to operate in parallel using our [[https://​www.victronenergy.com/​live/​victronconnect:​ve-smart-networking|wireless VE.Smart protocol]]; and at the same time it is part of an [[https://​www.victronenergy.com/​live/​ess:​start|Energy Storage System (ESS)]]. Or its used in an installation with an intelligent battery. In all those cases, the charger is being externally controlled ​(by ESS and/or intelligent battery), and should ​therefor ​not at the same time be configured for parallel operation.
  
 Resolution: disable the parallel operation by connecting VictronConnect,​ going to settings, then "​VE.Smart networking"​ and choose "Leave network"​. Resolution: disable the parallel operation by connecting VictronConnect,​ going to settings, then "​VE.Smart networking"​ and choose "Leave network"​.
mppt-error-codes.txt · Last modified: 2019-08-07 10:08 by mvader