mppt-error-codes [2019-05-06 13:58] – [Err 68 - Network misconfigured] mvadermppt-error-codes [2019-05-20 10:55] – [Err 116 - Calibration data lost] rvanzundert
Line 137: Line 137:
 If the error is only present in the history data and the unit operates normally this error can be ignored safely. Explanation: when the units power up for the very first time in the factory, it does not have calibration data and an error 116 is logged. Obviously this should have been cleared, but in the beginning units left the factory with this message still in the history data. If the error is only present in the history data and the unit operates normally this error can be ignored safely. Explanation: when the units power up for the very first time in the factory, it does not have calibration data and an error 116 is logged. Obviously this should have been cleared, but in the beginning units left the factory with this message still in the history data.
  
 +SmartSolar models (not the BlueSolar models): upgrading to v1.4x firmware is a one-way trip, you cannot go back to an older firmware version once you upgrade to v1.4x. Reverting to older firmware gives error 116 (calibration data lost), this can be fixed by re-installing the v1.4x firmware.
 ==== Err 119 - Settings data lost ==== ==== Err 119 - Settings data lost ====
 The charger cannot read its configuration, and stopped. The charger cannot read its configuration, and stopped.