mppt-error-codes
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | Next revisionBoth sides next revision | ||
mppt-error-codes [2019-05-06 13:46] – rvanzundert | mppt-error-codes [2019-05-06 13:58] – [Err 68 - Network misconfigured] mvader | ||
---|---|---|---|
Line 115: | Line 115: | ||
The charger detects multiple conflicting network sources trying to take control of the charger. | The charger detects multiple conflicting network sources trying to take control of the charger. | ||
- | All Smart Solar charger models: | + | Applies to SmartSolar MPPTs and SmartSolar MPPTs VE.Can. |
- | * If the charger | + | The typical reason for the error to show is that the charger |
- | VE.CAN Smart Solar chargers only: | + | Resolution: disable the parallel operation by connecting VictronConnect, |
- | * If the charger is connected via VE.CAN to a Venus GX device do not install a VE.Direct | + | For SmartSolar MPPT VE.Can only, also make sure its not connected |
Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute. | Once the conflict is resolved the error will disappear and the charger will resume normal operation, usually within a minute. |
mppt-error-codes.txt · Last modified: 2024-02-12 05:48 by guy_stewart