evchargingstation
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionLast revisionBoth sides next revision | ||
evchargingstation [2020-08-26 11:35] – [Description:] marmour | evchargingstation [2021-12-12 10:04] – [Installation:] lucian | ||
---|---|---|---|
Line 2: | Line 2: | ||
====== EV Charging Station ====== | ====== EV Charging Station ====== | ||
+ | ==== NOTE: DRAFT MANUAL. PRODUCT NOT AVAILABLE AND ALSO THERE IS NO ETA ==== | ||
Line 42: | Line 42: | ||
The device must be installed on a flat surface, recommended not in the in direct sunlight, so the screen can be read. | The device must be installed on a flat surface, recommended not in the in direct sunlight, so the screen can be read. | ||
- | To ensure maximum power will be delivered to the vehicle, cable cross-section must be 5x6mm2. There is no internal RCD, so an external one, closer to the Charging Station, must be installed. For this kind of applications, | + | To ensure maximum power will be delivered to the vehicle, cable cross-section must be at least 5x6mm2. There is no internal RCD, so an external one, closer to the Charging Station, must be installed. For this kind of applications, |
- | current of not greater than 30mA is recommended. | + | current of not greater than 30mA is recommended. |
+ | Ground connection is mandatory, without a proper one, the EV Charging station will fail. Based on your local electrical code, the ground (PE) should be correctly selected. For detecting the Ground presence, a small current (1mA) is injected on the Ground line. If a ground fault occurred, the EV Charging Station will periodically re-test it | ||
- | Start by opening the back cover. In the bottom left corner, there is a connector for powering the device. If it will be used on a single phase configuration, | + | Start by opening the back cover. In the bottom left corner, there is a connector for powering the device.(picture) |
+ | Before closing the back cover, make sure the rubber gasket is correctly attached. | ||
+ | Recommended torque for back cover screws:1Nm | ||
- | When the Ev Charging Station is powered up, it will start in access point mode. On the screen, the SSID name and password are visible, also the IP address of the device. You can either use that information to connect to it, or by scanning the QR Code displayed on the screen, it should ask if you want to automatically connect. | + | When the Ev Charging Station is powered up, it will start in access point mode. Start by scanning |
- | After a successful connection, in your browser, put the IP address of the device - default one is **192.168.0.1**, | + | After a successful connection, in your browser, put the IP address of the device - default one is **192.168.0.1**, |
Go to Setting/ | Go to Setting/ | ||
- | If used in a configuration with a GX device, to be able to charge using the excess power, the EV Charging Station must be configured to communicate with that GX device. In the ModbusTcp | + | If used in a configuration with a GX device, to be able to charge using the excess power, the EV Charging Station must be configured to communicate with that GX device. In the Settings/ |
Now on the main web page you should see the system information and the current flowing in this system | Now on the main web page you should see the system information and the current flowing in this system | ||
Line 65: | Line 68: | ||
===== Specifications: | ===== Specifications: | ||
- | * Unordered List ItemEv | + | * Ev Charging Station 22kW |
- | * Input voltage range (V AC) 170-265 | + | * Input voltage range (V AC): 170-265 |
- | * Rated charge current 32A/ | + | * Rated charge current: 32A/phase |
- | * Nominal power 22kW | + | * Nominal power: |
- | * Max. PV short circuit current | + | * Current output range: 6-32A |
- | * Wi-Fi standards 802.11 b/g/n | + | * Wi-Fi standards: 802.11 b/g/n (2.4Ghz only) |
- | * Self-consumption 15mA@230V | + | * Self-consumption: 15mA@230V |
- | * Configurable Max. Current 10-32A | + | * Configurable Max. Current: 10-32A |
- | * Configurable price/kWh (Eur) Default setting: 0.13 (adjustable) | + | * Means to Disconnect: |
- | * Control type Touch Screen, Web page, GX Device over ModbusTCP | + | * Configurable price/ |
- | * Light Ring 55 light configurable light effects available | + | * Control type: Touch Screen, Web page, GX Device over Modbus TCP |
- | * Protection External RCD is required | + | * Light Ring: 55 light configurable light effects available |
- | * Operating temperature -30 to +50°C | + | * Protection: External RCD is required |
- | * Humidity 95%, | + | * Operating temperature: -25°C to +50°C |
- | * Data communication | + | * Storage temperature: |
- | * ENCLOSURE Colour Blue (RAL 5012) | + | * Humidity: 95%, non-condensing |
- | * Power terminals 10 mm² / AWG7 | + | * Data communication: Modbus TCP over WIFI |
- | * Protection category IP43 (electronic components)??? | + | * ENCLOSURE Colour: Blue (RAL 5012) |
- | * Weight 3 kg | + | * Power terminals: 6-10 mm² / AWG 10-8 |
- | * Dimensions (h x w x d) 390 x 300 x 150 mm | + | * Protection category: IP44 |
- | * STANDARDS Safety IEC 61851-1, IEC 61851-22 ??? | + | * Ventilation: |
- | * Equipped with detection | + | * Weight: 3 kg |
+ | * Dimensions (h x w x d): 390 x 300 x 150 mm | ||
+ | * STANDARDS Safety: IEC 61851-1, IEC 61851-22 ??? | ||
+ | * Detection | ||
+ | * Detection for missing protective conductor | ||
+ | * Detection for missing Ground | ||
+ | * Detection for shorted CP | ||