Line 693: Line 693:
  
 (Make sure you install the ESS on L1. If it's installed on another phase the visualisation will be wrong.) (Make sure you install the ESS on L1. If it's installed on another phase the visualisation will be wrong.)
-==== 7.Three-phase ESS ====+==== 7.Three-phase ESS ====
  
 A three-phase ESS system has at least one Multi installed on each phase. We recommend leaving the phase-compensation setting to its default: enabled. A three-phase ESS system has at least one Multi installed on each phase. We recommend leaving the phase-compensation setting to its default: enabled.
Line 894: Line 894:
 Switching off in overload, while connected to the grid, is caused by the active Loss of Mains (LOM) detection, linked to the country code as configured in VEConfigure3. Switching off in overload, while connected to the grid, is caused by the active Loss of Mains (LOM) detection, linked to the country code as configured in VEConfigure3.
  
-This behaviour occurs when the AC supplied on the AC-in of the Multi or Quattro is 'weak'. By 'weak' we mean that the AC connection to the utility has a higher impedance than usual. For example a generator, or an old or remote house connected with a too-long and/or too/thin cable to the utility.+This behaviour occurs when the AC supplied on the AC-in of the Multi or Quattro is 'weak'. By 'weak' we mean that the AC connection to the utility has a higher impedance than usual. For example a generator, or house connected with a too-long and/or too-thin cable from the Inverter/Charger to the utility.
  
 For the solution and configuration options, see [[ve.bus:grid-codes-and-loss-of-mains-detection|]]. For the solution and configuration options, see [[ve.bus:grid-codes-and-loss-of-mains-detection|]].
Line 953: Line 953:
   - Now check MPPT Charge Voltage Setpoint. It is supposed to be above actual battery voltage.   - Now check MPPT Charge Voltage Setpoint. It is supposed to be above actual battery voltage.
  
-Note that those last two set points are determined by software; and calculated based on the setpoints sent by the (CANbus connected) lithium battery: you can'change change them manually. Looking at them however does help understanding why certain things are happening;+Note that those last two set points are determined by software; and calculated based on the setpoints sent by the (CANbus connected) lithium battery: you can't change them manually. Looking at them however does help understanding why certain things are happening;