Line 349: | Line 349: | ||
Set to ' | Set to ' | ||
+ | |||
+ | Please note that when enabling this option, the DVCC charge current limit configured under Settings -> Limit charge current won't be active. The Solar charger will operate at full power for maximum feed-in into the grid. It's advisable to configure a safe limit on the solar chargers when used with a small battery bank. | ||
=== 4.3.5 Phase compensation === | === 4.3.5 Phase compensation === | ||
Line 606: | Line 608: | ||
(This 0.1 V is the threshold for 12 V systems; for 24 V the threshold is 0.2 V above; and for 48 V it is 0.4V above.) | (This 0.1 V is the threshold for 12 V systems; for 24 V the threshold is 0.2 V above; and for 48 V it is 0.4V above.) | ||
- | ==== 6.5 ESS Battery Status Code Numbers ==== | + | ==== 6.5 ESS Battery Status |
In addition to the charger states (Bulk/ | In addition to the charger states (Bulk/ |