===== 1. Selection guide ===== | ===== 1. Selection guide ===== | ||
- | ^ __Energy Meter__ | + | ^ __Energy Meter__ |
- | | Appearance | + | | Appearance |
- | | Display | + | | Display |
- | | Manual and Wiring Diagrams* | [[et112|ET112 Manual]] | + | | Manual and Wiring Diagrams | [[et112|ET112 Manual]] |
- | | Part Number | REL300100000 | + | | Part Number | REL300100000 |
- | | Supported Phases | 1 phase | 3 phase | 3 phase | + | | Supported Phases | 1 phase | 3 phase ||| |
- | | Maximum Current Rating | 100A | 65A per phase | 65A per phase | + | | Maximum Current Rating | 100A | 65A per phase ||| |
- | | Measurement Type | Shunt | | + | | Measurement Type | Shunt |
+ | | Data connection | ||
- | * Including RS485 to GX device instructions. | ||
=== First decide if you need single- or three phase meters === | === First decide if you need single- or three phase meters === | ||
- | For a three phase utility connection, use a three phase meter. For a three phase PV Inverter, use a three phase meter as well. For a single phase utility connection, use a single phase meter. And in an installation with a single phase utility connection, that also has a PV Inverter that needs measuring with a Victron meter, then you can use Rutger | + | For a three phase utility connection, use a three phase meter. For a three phase PV Inverter, use a three phase meter as well. For a single phase utility connection, use a single phase meter. And in an installation with a single phase utility connection, that also has a PV Inverter that needs measuring with a Victron meter, then you can use 2 pieces of ET112; or use the ET340. |
- | === Now, based on current, select the model === | + | === Now, based on current, select the model: === |
^ Requirement | ^ Requirement | ||
| Single phase up to 100A | Shunt | ET112 | | | Single phase up to 100A | Shunt | ET112 | | ||
Line 29: | Line 29: | ||
| Three phase more than 65A/ | | Three phase more than 65A/ | ||
- | The EM24 meter counts energy in a different way than the ET340. For Germany and most other countries; the EM24 is the advised model. See FAQ Q5 and Q9 for further details. | + | The EM24 meter counts energy in a different way than the ET340. For Germany and most other countries; the EM24 is the advised model. See FAQ Q5 and Q9 for further details |
- | === 1.1 Support for other Carlo Gavazzi meters === | + | === In case of EM24, select between RS485 and Ethernet connection: === |
+ | |||
+ | The Ethernet model will have an advantage in installations where an Ethernet network is available. Rather than having to pull an RS485 wire between the main AC distribution board and the storage system, the existing Ethernet can be used. | ||
+ | |||
+ | The disadvantage is that this relies on that network functioning properly - in case of issues the Storage system will switch to idle mode: passthrough. | ||
+ | |||
+ | ===== 2. Support for other Carlo Gavazzi meters | ||
Besides above listed meters, there are many more meters available from Carlo Gavazzi. Use this list to see which ones are compatible. | Besides above listed meters, there are many more meters available from Carlo Gavazzi. Use this list to see which ones are compatible. | ||
Line 111: | Line 117: | ||
* USB485-STIXL : Isolated USB to RS485 converter | * USB485-STIXL : Isolated USB to RS485 converter | ||
+ | |||
+ | === Q11: Can I use Victron energy meters instead of a Victron Inverter/ | ||
+ | |||
+ | Energy meters are intended only to supplement a Victron inverter charger in the system. | ||
+ | Energy Meters are currently limited in their potential applications. Each energy meter is only intended to provide a specific piece of additional information - total loads on AC input and grid import/ | ||
+ | |||
+ | {{: | ||
+ | |||
+ | They cannot be used for other purposes e.g. to measure specific, arbitrary AC loads or circuits for example. | ||
+ | They should also not be considered a replacement to having a Victron inverter / charger. Attempting to use other brand battery inverters and trying to substitute their lack of data connectivity to the GX device by using energy meters will not work. | ||