User Tools

Site Tools


energy-meters:et340

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
energy-meters:et340 [2019-01-21 11:09]
ictbeheer [DISQUS]
energy-meters:et340 [2019-09-08 17:45] (current)
mvader
Line 1: Line 1:
 ====== Energy Meter ET340 manual ====== ====== Energy Meter ET340 manual ======
 {{ :​energy-meters:​energy_meter_et340_right_.png?​nolink&​200|}} {{ :​energy-meters:​energy_meter_et340_right_.png?​nolink&​200|}}
- 
  
  
Line 8: Line 7:
 This document is the manual for the 3 phase max 65A per phase Energy Meter. This document is the manual for the 3 phase max 65A per phase Energy Meter.
  
-The Energy Meter can be used for four things:+The Energy Meter can be used to:
  
   - Grid meter, and used as control input for an [[assistants:​ess-assistant|ESS System]] (1).   - Grid meter, and used as control input for an [[assistants:​ess-assistant|ESS System]] (1).
Line 18: Line 17:
   - Direct connection, either using the RS485 to USB interface with 1.8m cable length, or the 5.0m cable.   - Direct connection, either using the RS485 to USB interface with 1.8m cable length, or the 5.0m cable.
   - Wireless connection via Zigbee   - Wireless connection via Zigbee
- 
-Note that this model is not stocked by Victron Energy, we recommend to purchase it locally. 
  
 ===== 2. AC Wiring ===== ===== 2. AC Wiring =====
Line 81: Line 78:
 {{ :​energy-meters:​em340_settings_detail.png?​nolink |}} {{ :​energy-meters:​em340_settings_detail.png?​nolink |}}
  
-==== 4. Multiple Energy Meters in one system ====+===== 4. Multiple Energy Meters in one system ​=====
  
 To connect multiple Energy Meters, wire each meter to a separate RS485-USB converter. Which are then each plugged into a separate USB socket on the CCGX. To connect multiple Energy Meters, wire each meter to a separate RS485-USB converter. Which are then each plugged into a separate USB socket on the CCGX.
Line 87: Line 84:
 Connecting multiple ET340 meters to the same RS485-USB cable is not possible: the ET340 meter has no display and its Modbus address can therefor not be changed. Connecting multiple ET340 meters to the same RS485-USB cable is not possible: the ET340 meter has no display and its Modbus address can therefor not be changed.
  
 +===== DISQUS =====
 +~~DISQUS~~
  
energy-meters/et340.1548065389.txt.gz · Last modified: 2019-01-21 11:09 by ictbeheer