energy-meters:et340 [2019-01-21 13:13] – [1. Introduction and usage] guy_stewartenergy-meters:et340 [2020-06-27 13:23] – [Option A: wireless Zigbee connection] - note on compatibility boekel
Line 1: Line 1:
 ====== Energy Meter ET340 manual ====== ====== Energy Meter ET340 manual ======
 {{ :energy-meters:energy_meter_et340_right_.png?nolink&200|}} {{ :energy-meters:energy_meter_et340_right_.png?nolink&200|}}
- 
  
  
Line 18: Line 17:
   - Direct connection, either using the RS485 to USB interface with 1.8m cable length, or the 5.0m cable.   - Direct connection, either using the RS485 to USB interface with 1.8m cable length, or the 5.0m cable.
   - Wireless connection via Zigbee   - Wireless connection via Zigbee
- 
  
 ===== 2. AC Wiring ===== ===== 2. AC Wiring =====
Line 57: Line 55:
 Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again. Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again.
  
 +=== note on old and new zigbee converters ===
 +Please note that there is a new zigbee converter available now, that is -not- backwards compatible with the old converters. If you have a non compatible set, please ask your supplier for a correct version.
 +
 +'old' type: 
 +
 +ASS300400100 - Zigbee to RS485 converter partnumber: DRF2619C
 +
 +ASS300400100 - Zigbee to USB converter   partnumber: DRF2618A
 +
 +'new' type:
 +
 +ASS300420100 - Zigbee to RS485 converter partnumber: DRF2659C
 +
 +ASS300420200 - Zigbee to USB converter   partnumber: DRF2658C
 ==== Option B: Wired connection to CCGX ==== ==== Option B: Wired connection to CCGX ====
  
Line 80: Line 92:
 {{ :energy-meters:em340_settings_detail.png?nolink |}} {{ :energy-meters:em340_settings_detail.png?nolink |}}
  
-==== 4. Multiple Energy Meters in one system ====+===== 4. Multiple Energy Meters in one system =====
  
 To connect multiple Energy Meters, wire each meter to a separate RS485-USB converter. Which are then each plugged into a separate USB socket on the CCGX. To connect multiple Energy Meters, wire each meter to a separate RS485-USB converter. Which are then each plugged into a separate USB socket on the CCGX.
  
 Connecting multiple ET340 meters to the same RS485-USB cable is not possible: the ET340 meter has no display and its Modbus address can therefor not be changed. Connecting multiple ET340 meters to the same RS485-USB cable is not possible: the ET340 meter has no display and its Modbus address can therefor not be changed.
 +