energy-meters:et340
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revisionNext revisionBoth sides next revision | ||
energy-meters:et340 [2017-07-19 14:49] – [Energy Meter ET340 manual] martijncoster | energy-meters:et340 [2019-01-21 13:13] – [1. Introduction and usage] guy_stewart | ||
---|---|---|---|
Line 1: | Line 1: | ||
====== Energy Meter ET340 manual ====== | ====== Energy Meter ET340 manual ====== | ||
- | {{ : | + | {{ : |
Line 8: | Line 8: | ||
This document is the manual for the 3 phase max 65A per phase Energy Meter. | This document is the manual for the 3 phase max 65A per phase Energy Meter. | ||
- | The Energy Meter can be used for four things: | + | The Energy Meter can be used to: |
- Grid meter, and used as control input for an [[assistants: | - Grid meter, and used as control input for an [[assistants: | ||
Line 19: | Line 19: | ||
- Wireless connection via Zigbee | - Wireless connection via Zigbee | ||
- | Note that this model is not stocked by Victron Energy, we recommend to purchase it locally. | ||
===== 2. AC Wiring ===== | ===== 2. AC Wiring ===== | ||
=== 3-phase diagram: === | === 3-phase diagram: === | ||
- | {{: | + | {{: |
When used to measure a PV Inverter, terminals 1, 2 and 3 should face the PV inverter to ensure correct direction of current and power. | When used to measure a PV Inverter, terminals 1, 2 and 3 should face the PV inverter to ensure correct direction of current and power. | ||
Line 32: | Line 31: | ||
In this diagram, a single meter is used to both measure the grid and a single phase PV Inverter. | In this diagram, a single meter is used to both measure the grid and a single phase PV Inverter. | ||
- | {{: | + | {{: |
On the CCGX go to the grid meter in the Wired AC sensor settings. Make sure 'Phase type' is set to ' | On the CCGX go to the grid meter in the Wired AC sensor settings. Make sure 'Phase type' is set to ' | ||
Line 86: | Line 85: | ||
Connecting multiple ET340 meters to the same RS485-USB cable is not possible: the ET340 meter has no display and its Modbus address can therefor not be changed. | Connecting multiple ET340 meters to the same RS485-USB cable is not possible: the ET340 meter has no display and its Modbus address can therefor not be changed. | ||
- | |||
- | ===== DISQUS ===== | ||
- | ~~DISQUS~~ | ||
energy-meters/et340.txt · Last modified: 2022-07-15 10:58 by stefanie