energy-meters:et112 [2020-05-27 10:19] – [Option A: wireless Zigbee connection] guy_stewartenergy-meters:et112 [2020-06-29 22:45] – [Option A: wireless Zigbee connection] added min. Venus version boekel
Line 67: Line 67:
 Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again. Connect the 12V DC power supply to the Zigbee to RS485 converter. When the power is switched on, check the LEDs again.
  
 +=== note on old and new zigbee converters ===
 +Please note that there is a new zigbee converter available now, that is -not- backwards compatible with the old converters. If you have a non compatible set, please ask your supplier for a correct version.
 +
 +'old' type: 
 +
 +ASS300400100 - Zigbee to RS485 converter partnumber: DRF2619C
 +
 +ASS300400100 - Zigbee to USB converter   partnumber: DRF2618A
 +
 +'new' type:
 +
 +ASS300420100 - Zigbee to RS485 converter partnumber: DRF2659C
 +
 +ASS300420200 - Zigbee to USB converter   partnumber: DRF2658C
 +
 +
 +
 +== note on GX firmware versions: ==
 +for the new type Zigbee converters, Venus OS v2.54 is the minimum required software version
 ==== Option B: Wired connection to CCGX ==== ==== Option B: Wired connection to CCGX ====
  