drafts:sa_system:dcsolar3000
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revisionLast revisionBoth sides next revision | ||
drafts:sa_system:dcsolar3000 [2015-04-13 09:48] – created martijncoster | drafts:sa_system:dcsolar3000 [2019-01-22 10:16] – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
- | ====== MultiPlus | + | ====== MultiPlus |
=== Introduction === | === Introduction === | ||
(Explain what it solves:) \\ | (Explain what it solves:) \\ | ||
Nog geen verhaal geschreven alleen voor de plaatjes!!. \\ | Nog geen verhaal geschreven alleen voor de plaatjes!!. \\ | ||
+ | Battery charged using solar power \\ | ||
+ | ------- \\ | ||
When mains power is available the loads are powered directly. \\ | When mains power is available the loads are powered directly. \\ | ||
- | If the mains is not available because of load shedding the loads powered with the energy from the batteries. When the mains is available again the power will be supplied directly from the mains and the batteries will be charged again.\\ | + | If the mains is not available because of load shedding the loads powered with the energy from solar and the batteries. When the mains is available again the power will ...\\ |
== How long is the backup time? == | == How long is the backup time? == | ||
- | The backup time depends on the power consumption.\\ | + | The backup time depends on the power consumption |
If the power consumption is high like during the day then time available will be short. During the night when power consumption is low the time the power can be supplied by the batteries will be longer. | If the power consumption is high like during the day then time available will be short. During the night when power consumption is low the time the power can be supplied by the batteries will be longer. | ||
* Load shedding period: High power loads about 1600W DoD 50% SoC about 2 hours runtime | * Load shedding period: High power loads about 1600W DoD 50% SoC about 2 hours runtime | ||
Line 22: | Line 24: | ||
* MultiPlus | * MultiPlus | ||
* Batterybank | * Batterybank | ||
+ | * 2 MPPT solar chargers | ||
+ | * BMV702 | ||
Connect the AC input to the mains. Connect the AC to the loads you want to backup.\\ | Connect the AC input to the mains. Connect the AC to the loads you want to backup.\\ | ||
- | Connect the battery cables to the battery. Read the manual for details on how to safely connect the batteries\\ | + | Connect the battery cables to the battery. Read the manual for details on how to safely connect the batteries.\\ |
+ | Verder uitwerken!! | ||
\\ | \\ | ||
=== Parts === | === Parts === | ||
- | * 1x - PMP243021010 - [[http:// | + | * 1x - PMP243021010 - [[https:// |
- | * 4x - BAT412201080 - [[http:// | + | * 4x - BAT412201080 - [[https:// |
- | * or - BAT412201100 - [[http:// | + | * or - BAT412201100 - [[https:// |
* 4x - Battery link cables | * 4x - Battery link cables | ||
+ | * 2x - MPPT Solar Charger | ||
+ | * ??x Panelen (Victron panelen erbij?? Welke dan??) | ||
+ | * 1x - BMV702 | ||
- | {{ : | + | {{ : |
=== Advanced system === | === Advanced system === | ||
Line 39: | Line 47: | ||
\\ | \\ | ||
=== optional parts=== | === optional parts=== | ||
- | * DMC000200000R - [[http:// | + | * DMC000200000R - [[https:// |
- | * BPP000300100R - [[http:// | + | * BPP000300100R - [[https:// |
- | {{ : | + | \\ |
+ | Plaatje nog aanpassen dat VEDirect is aangesloten en Battery Balancer toevoegen \\ | ||
+ | \\ | ||
+ | {{ : | ||
== Notes for batteries: == | == Notes for batteries: == | ||
* We recommend using deep-cycle GEL or AGM batteries. At least 200Ah blocks. | * We recommend using deep-cycle GEL or AGM batteries. At least 200Ah blocks. | ||
- | * Cable cross section: The Multiplus 1600 comes with battery cables of 1.5m included. These cables are 35mm2 thick. If longer cables are needed a cable with a thicker crosssection may be needed. Check the table in this document: [[http:// | + | * Cable cross section: The Multiplus 1600 comes with battery cables of 1.5m included. These cables are 35mm2 thick. If longer cables are needed a cable with a thicker crosssection may be needed. Check the table in this document: [[https:// |
\\ | \\ | ||
=== VE.Configure Settings === | === VE.Configure Settings === | ||
Line 52: | Line 63: | ||
This can be dowloaded from our website. On our website there is also documentation avaiable that explains how VE.Configure should be used. | This can be dowloaded from our website. On our website there is also documentation avaiable that explains how VE.Configure should be used. | ||
\\ | \\ | ||
- | * [[http:// | + | * [[https:// |
- | * [[http://http:// | + | * [[https:// |
- | * [[http:// | + | * [[https:// |
== Settings == | == Settings == | ||
Line 73: | Line 84: | ||
{{ : | {{ : | ||
- | ===== DISQUS Comments ===== | ||
+ | ===== DISQUS ===== | ||
~~DISQUS~~ | ~~DISQUS~~ | ||