drafts:mppt_faq [2018-09-22 11:12] john_rdrafts:mppt_faq [2019-06-05 15:59] – [Q8: Can I connect different panels to the same charge controller?] mvader
Line 32: Line 32:
 1. Check that the PV voltage is high enough compared to the battery voltage. Either read it with a remote panel or VictronConnect. 1. Check that the PV voltage is high enough compared to the battery voltage. Either read it with a remote panel or VictronConnect.
  
-Or measure the voltage with a Volt meter. Make sure to measure the voltage on the terminals on the charger. Not elsewhere, to rule out any faulty wires or fuses. The panel voltage needs to be at least 5V above the battery voltage for the charger to start power conversion; see the manual for more information.+Or measure the voltage with a Volt meter. Make sure to measure the voltage on the terminals on the charger. Not elsewhere, to rule out any faulty wires or fuses. The panel voltage needs to be at least 5V above the battery voltage for the charger to start power conversion; [[https://www.victronenergy.com/support-and-downloads/manuals|see the manual for more information]].
  
 2. For models with a Remote on/off switch (a green two pole connector, labelled Remote L H), check that the jumper is in. L and H need to be shorted for the unit to switch on. Only the large models have this connector, see datasheet for details. 2. For models with a Remote on/off switch (a green two pole connector, labelled Remote L H), check that the jumper is in. L and H need to be shorted for the unit to switch on. Only the large models have this connector, see datasheet for details.
Line 41: Line 41:
  
 If all above is fine, and still the unit does not operate, contact a dealer to have the unit tested. If all above is fine, and still the unit does not operate, contact a dealer to have the unit tested.
- 
 ==== Q7: Can I use the MPPT Solar Charger as DC-DC charger? ==== ==== Q7: Can I use the MPPT Solar Charger as DC-DC charger? ====
  
 For example to charge a 12 Volt battery from a 24V battery bank? For example to charge a 12 Volt battery from a 24V battery bank?
  
-Yes.+No.
  
 ==== Q8: Can I connect different panels to the same charge controller? ==== ==== Q8: Can I connect different panels to the same charge controller? ====
Line 52: Line 51:
 No. Under no circumstances. No. Under no circumstances.
  
-===== DISQUS Comments =====+==== Q9: Can I use panels with optimisers? ====
  
 +No.
 +===== DISQUS =====