drafts:error_codes
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revision | Next revisionBoth sides next revision | ||
drafts:error_codes [2020-09-11 09:53] – rvanzundert | drafts:error_codes [2020-09-16 13:49] – rvanzundert | ||
---|---|---|---|
Line 151: | Line 151: | ||
This error will not auto-reset. Check the installation and restart the unit using the power-switch. | This error will not auto-reset. Check the installation and restart the unit using the power-switch. | ||
- | ==== Err 50 - Inverter overload ==== | + | ==== Err 50, Err 52 - Inverter overload, Inverter peak current |
Some loads like motors or pumps draw large inrush currents in a start-up situation. In such circumstances, | Some loads like motors or pumps draw large inrush currents in a start-up situation. In such circumstances, | ||
+ | |||
+ | The Inverter can supply more power than the nominal power level for a short time. If the time is exceed the inverter stops. | ||
After three restarts followed by another overload within 30 seconds of restarting, the inverter will shutdown and remain off. To restart the inverter, switch it Off, then On. | After three restarts followed by another overload within 30 seconds of restarting, the inverter will shutdown and remain off. To restart the inverter, switch it Off, then On. | ||
Line 163: | Line 165: | ||
The inverter will restart after 30 seconds. The inverter will not stay off after multiple retries. | The inverter will restart after 30 seconds. The inverter will not stay off after multiple retries. | ||
- | |||
- | ==== Err 52 - Inverter excessive current ==== | ||
- | If the error persists reduce the load on the AC out terminal by switching off or disconnecting appliances. | ||
- | |||
- | This error will auto-restart after 30s, after 3 attempts the unit shuts down and a power-cycle is needed to restart the unit. | ||
==== Err 53, Err 54 - Inverter output voltage ==== | ==== Err 53, Err 54 - Inverter output voltage ==== | ||
Line 174: | Line 171: | ||
==== Err 57 - Inverter ac voltage on output ==== | ==== Err 57 - Inverter ac voltage on output ==== | ||
- | There is already AC voltage on the AC out terminal before switching on the inverter. Check if the AC out is not connected to a mains outlet or to another inverter. | + | There is already AC voltage on the AC out terminal before switching on the inverter. Check that the AC out is not connected to a mains outlet or to another inverter. |
This error will not auto-reset. Check the installation and restart the unit using the power-switch. | This error will not auto-reset. Check the installation and restart the unit using the power-switch. |